LIC-INCORROUT MSDMGR FIX COPY MEDIA ERROR

Error Description

Moved the add setting of the load date field in module info back
to R720 and R730.                                              
The above fix was already in R740, so the R740 PTFs only        
contain the fix below                                          
Fix error notification when SfdvCopyMediaToLibraryWorkUnit      
fails.                                                          

Problem Summary

A error during a copy from media (tape) to the MSDMgr hangs    
trying to display a error message.                              
Task    359: TDE=B003D00005364000 TaskName=SFDV                
WaitObj=D913ED1642A58A00 QMP-QuMessagePool                      
WaitObjCaller=FFFFFFFFFF2E7318 module QuMessagePoolCode+0xDF8  
ISF=EF12DFCE15FFBC40 NIA=FFFFFFFFFF2E67B8 module                
QuMessagePoolCode+0x298                                        
ISF=EF12DFCE15FFBD00 NIA=FFFFFFFFFF2E7318 module                
QuMessagePoolCode+0xDF8                                        
ISF=EF12DFCE15FFBD60 NIA=FFFFFFFFF6BAFA3C module                
ServiceFunctionSessionInfo+0x2E9C                              
ISF=EF12DFCE15FFBFC0 NIA=FFFFFFFFF528B0C8 module                
ExInvokeDtr+0xB8                                                
ISF=EF12DFCE15FFC0C0 NIA=FFFFFFFFF528A2B4 module                
ExProcessCleanupHandlers+0x9B4                                  
ISF=EF12DFCE15FFC340 NIA=FFFFFFFFFF0D47FC module                
ExExceptHighUse+0xDFC                                          
ISF=EF12DFCE15FFCA40 NIA=FFFFFFFFFF0D5798 module                
ExExceptHighUse+0x1D98                                          
ISF=EF12DFCE15FFD1A0 NIA=FFFFFFFFC817AC1C module                
SfdvScreenTaskEntry+0xC0C                                      
ISF=EF12DFCE15FFE000 NIA=FFFFFFFFF6BB1DE0 module                
ServiceFunctionScreenDriver+0x560                              
ISF=EF12DFCE15FFEE60 NIA=FFFFFFFFF6BB22FC module                
ServiceFunctionMsgTranslator+0x34C                              
ISF=EF12DFCE15FFF020 NIA=FFFFFFFFF6BB2AD0 module                
ServiceFunctionInfoMsgPacket+0x120                              
ISF=EF12DFCE15FFF140 NIA=FFFFFFFFF6BB0B54 module                
ServiceFunctionScreens+0xF64                                    
ISF=EF12DFCE15FFF280 NIA=FFFFFFFFC570F4A4 module                
SfdvMsdCopiesWorkUnit+0x1EC4                                    
ISF=EF12DFCE15FFF5C0 NIA=FFFFFFFFF6BB1BF0 module                
ServiceFunctionScreenDriver+0x370                              
ISF=EF12DFCE15FFF7A0 NIA=FFFFFFFFC817AAD8 module                
SfdvScreenTaskEntry+0xAC8                                      
ISF=EF12DFCE15FFFCE0 NIA=FFFFFFFFF61A4AA8 module #sdtcmod+0x178
ISF=EF12DFCE15FFFE80 NIA=FFFFFFFFFFFD48DC module                
rmInitialRoutine+0x5C                                          
ISF=EF12DFCE15FFFEC0 NIA=0000000000000000 Not valid instruction
address                                                        

Problem Conclusion

The hang is caused when the error message number from the      
failure is not copied into a info message and this causes the  
message handler to hang on an exception when the error number is
zero. The LIC was changed to copy the error message number into
the info message.                                              
                                                               
Note the hang is only a job hang. The job can be canceled but  
the SLIC MSDMgr (SFDV) task will still be hung. The hung SFDV  
task doesn't prevent new MSDMgr requests. The LIC SFDV task can
only be ended by IPLing the partition.                          

Temporary Fix

Comments

Circumvention


PTFs Available

R720 MF65680   9123
R730 MF65681   9116
R740 MF65832   9151

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 9400DG300
Failing Module.......................... RCHMGR
Reported Release................... R730
Duplicate Of..............................




IBM i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019, 2020 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.1.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R2M0;V7R3M0;V7R4M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
09 January 2020