MA46417 - OSP-DB-OTHER-MSGCPF523B AFTER A SYSTEM CRASH SOME PARTITIONS OF A FILE WERE NOT ABLE TO BE UPDATED DUE TO CHECK PENDING STATE

 APAR (Authorized Program Analysis Report)

Abstract

OSP-DB-OTHER-MSGCPF523B AFTER A SYSTEM CRASH SOME PARTITIONS OF
A FILE WERE NOT ABLE TO BE UPDATED DUE TO CHECK PENDING STATE

Error Description

AFTER A SYSTEM CRASH SOME PARTITIONS OF A FILE WERE NOT ABLE TO
BE UPDATED DUE TO CHECK PENDING STATE THIS WAS AN INTERNAL      
CHECK CONSTRAINT USED TO ENSURE THE DATA IS IN THE PROPER      
PARTITION. USER HAS NO ACCESS TO THE CONSTRAINT.                

Problem Summary

****************************************************************
* PROBLEM: (MA46417) Licensed Program = 5770999 for i 7.1,     *
*                                        i 7.2, and i 7.3      *
*          Base System Function-Work Management, Install, PTF. *
*            Database partitioned table constraints after crash*
****************************************************************
* USERS AFFECTED: All IBM i operating system users.            *
****************************************************************
* RECOMMENDATION: Apply LIC PTF MF63697 for i 7.1.             *
*                 Apply LIC PTF MF63698 for i 7.2.             *
*                 Apply LIC PTF MF63699 for i 7.3.             *
****************************************************************
AFTER A SYSTEM CRASH SOME PARTITIONS OF A FILE WERE NOT ABLE TO
BE UPDATED DUE TO CHECK PENDING STATE THIS WAS AN INTERNAL CHECK
CONSTRAINT USED TO ENSURE THE DATA IS IN THE PROPER PARTITION.  
USER HAS NO ACCESS TO THE CONSTRAINT.                          

Problem Conclusion

The code processing at IPL time is properly moving the          
constraints to check pending, but its in general code that is  
normally "runtime" in nature.  So, its generating a VLOG        
(0600-64C9) and an event.  However, since this is IPL (pre-XPF),
we need an ORL instead of an event. The code is being updated  
which will generate an ORL and the XPF DB processing will put  
the file on edtcpcst and verify the constraint.                

Temporary Fix

                       *********                                
                       * HIPER *                                
                       *********                                

Comments

Circumvention


PTFs Available

R710 MF63697 PTF Cover Letter   1000
R720 MF63698 PTF Cover Letter   7290
R730 MF63699 PTF Cover Letter   7283

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... Yes
Component.................................. 9400DG3DB
Failing Module.......................... RCHMGR
Reported Release................... R710
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information