IBM Support

MA46099 - INCORROUT - HLIC - 94XXDASD

 APAR (Authorized Program Analysis Report)

Abstract

INCORROUT - HLIC - 94XXDASD

Error Description

Corrects a possible undetected data corruption in rare cases    
when the drive is in error recovery during a sequential write  
command and the drive is reset or there is a power loss.  There
is no known occurrence on Power Systems for data corruption for
this issue.  However, IBM recommends that all customers with    
these drives apply the latest level of code.                    

Problem Summary

****************************************************************
* PROBLEM: (MA46099) Licensed Program = 5770999 for i 7.1,     *
*                                        i 7.2, and i 7.3      *
*           Usability of a Product's MAJOR Function            *
*            Code Improvement                                  *
****************************************************************
* USERS AFFECTED: All IBM i operating system 94xx users.       *
****************************************************************
* RECOMMENDATION: Apply LIC PTF MF63039 for i 7.1.             *
*                 Apply LIC PTF MF63040 for i 7.2.             *
*                 Apply LIC PTF MF62041 for i 7.3.             *
****************************************************************
Corrects a possible undetected data corruption in rare cases    
when the drive is in error recovery during a sequential write  
command and the drive is reset or there is a power loss.  There
is no known occurrence on Power Systems for data corruption for
this issue.  However, IBM recommends that all customers with    
these drives apply the latest level of code.                    

Problem Conclusion

Code level 6805                                                
                                                               
- Corrects a possible undetected data corruption in rare cases  
when the drive is in error recovery during a sequential write  
command and the drive is reset or there is a power loss.  There
is no known occurrence on Power Systems for data corruption for
this issue.  However, IBM recommends that all customers with    
these drives apply the latest level of code.                    

Temporary Fix

                       *********                                
                       * HIPER *                                
                       *********                                

Comments

Circumvention


PTFs Available

R710 MF63039 PTF Cover Letter   7192
R720 MF63040 PTF Cover Letter   7068
R730 MF63041 PTF Cover Letter   7061

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... Yes
Component.................................. 9400DGP00
Failing Module.......................... RCHMGR
Reported Release................... R710
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

Document information

More support for: i family

Software version: V7R1M0, V7R2M0, V7R3M0

Operating system(s): OS/400

Reference #: MA46099

Modified date: 28 July 2017