Abstract
OSP-COMM-ELAN-PERFM DEVICE DRIVER NOT RECEIVING INTERRUPTS
Error Description
SRIOV capable cards 26E4 has problem with not receiving packets
in a timely manner.
The problem with a delay 1/16th (0.0625) of a seconds occurs
when a line description is ONLINE(*YES) or an associated
interface is AUTOSTART(*YES). A Sniffer network trace will see
a delay in the .064 or .065 of a second for response.
Problem Summary
****************************************************************
* PROBLEM: (MA45524) Licensed Program = 5770999 for i 7.1, *
* i 7.2, and i 7.3 *
* Severe Performance Degradation *
* Severe performance degradation of the Ethernet *
* adapter. *
****************************************************************
* USERS AFFECTED: All IBM i operating system users with *
* Ethernet adapters with CCINs 2B93, 2C4C, *
* 2C4D, 2CC0, 2CC1, 2CE3, or 2CE4. *
****************************************************************
* RECOMMENDATION: Apply LIC PTF MF61852 for i 7.1. *
* Apply LIC PTF MF61863 for i 7.2. *
* Apply LIC PTF MF61864 for i 7.3. *
****************************************************************
*****
There is a problem with Ethernet device drivers not receiving
packets in a timely manner. The customer was seeing a delay of
approximately .065 of a second for a response with a sniffer
network trace with a ping test. This behavior can be observed
with adapters with CCINs 2B93, 2C4C, 2C4D, 2CC0, 2CC1, 2CE3, or
2CE4. Varying the line description off and on corrected the
performance issue.
Problem Conclusion
The symptoms seen by the customer are due to the device driver
not receiving interrupts. This is caused by a multi-threading
issue which is seen if multiple CMN resources on a device are
being activated simultaneously. This is more likely to happen
if the CMN resources have line descriptions with ONLINE(*YES)
specified or if those line descriptions are associated with
interfaces with AUTOSTART(*YES).
This PTF will fix the multi-threading problem with interrupt
setup and the device driver performance issue should be
corrected.
Additional keywords:
65 ms milliseconds
inbound
Temporary Fix
*********
* HIPER *
*********
Comments
Circumvention
PTFs Available
R710 MF61852 6320
R720 MF61863 6306
R730 MF61864 6299
Affected Modules
Affected Publications
Summary Information
Status............................................ | CLOSED PER |
HIPER........................................... | Yes |
Component.................................. | 9400DG300 |
Failing Module.......................... | RCHMGR |
Reported Release................... | R710 |
Duplicate Of.............................. |
System i Support
IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information