Subscribe to this APAR
By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.
APAR (Authorized Program Analysis Report) |
Abstract
LIC-MEDIA-OPT-MSGOPT1360 Volumes with *HPOFS file system
Error Description
When a *PWORM or *ERASE media from an earlier i release are
moved to v7r2, none of the data can be accessed. Lic Logs may be
created, including 3A00 1000, and 3A00 1005, and operations to
the library report errors, the most common being OPT1360 Media
directory corrupted.
Problem Summary
****************************************************************
* PROBLEM: (MA44380) Licensed Program = 5770999 for i 7.2 *
* Incorrect Output Causes a Severe Problem *
****************************************************************
* USERS AFFECTED: All IBM i operating system users with optical*
* *WORM or *ERASE media using the *HPOFS file *
* system. *
****************************************************************
* RECOMMENDATION: Apply LIC PTF MF59724 for i 7.2. *
****************************************************************
#####
When a *PWORM or *ERASE media from an earlier IBM i release are
moved to IBM i 7.2, none of the data can be accessed. Lic Logs
may be created, including 3A00 1000, and 3A00 1005, and
operations to the library report errors, the most common being
MSGOPT1360 Media directory corrupted.
Service Keywords:
*HPOFS HPOFS
VL3A001000 3A001000 3A00 1000
Problem Conclusion
There is a LIC error in the base IBM i 7.2 code that changed the
expected location of data on the media. Apply this fix to
correct the file system processing and the data on *HPOFS media
from earlier releases may be accessed. Warning: When this PTF
is applied, any media that was initialized on v7r2 with INZOPT
MEDFMT(*HPOFS), or with INZOPT MEDFMT(*MEDTYPE) when the media
type is *WORM or *ERASE will not be usable after this PTF is
applied. Files should be copied off of the *HPOFS media before
applying this PTF.
Temporary Fix
*********
* HIPER *
*********
Comments
Circumvention
PTFs Available
Affected Modules
Affected Publications
Summary Information
Status............................................ | CLOSED PER |
HIPER........................................... | Yes |
Component.................................. | 9400DG300 |
Failing Module.......................... | RCHMGR |
Reported Release................... | R720 |
Duplicate Of.............................. |
System i Support
IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information