IBM Support

Upgrade CICSTS54, Subset JCI710M

  Preventive Service Planning

Upgrade CICSTS54, Subset JCI710M


Upgrade CICSTS54, Subset JCI710M:

This subset contains installation information for CICSPlex System Mgr
Version 5, Release 4, Modification 0.


Change Summary

DATE LAST CHANGED SECTION 1. YY/MM/DD INSTALLATION INFORMATION NO ENTRIES 2. YY/MM/DD DOCUMENTATION CHANGES NO ENTRIES 3. 17/09/01 GENERAL INFORMATION 4. 18/03/26 SERVICE RECOMMENDATIONS 5. YY/MM/DD CROSS PRODUCT DEPENDENCIES NO ENTRIES


Service Recommendation Summary

DATE APAR PTF VOLID COMMENTS 8 18/03/26 PI94526 UI54649 1000 HIPER CPSM S0C4 ASRA ABEND IN 7 18/03/01 PI93834 UI54089 1802 HIPER DEFECT 146636 6 18/02/05 PI92852 UI53571 1802 HIPER SHIP CORRECT MAS GENERIC 5 18/02/02 PI90941 UI53578 1801 HIPER CPSM WLM ROUTING MAY 4 17/10/30 PI88323 UI51380 1710 HIPER EYUXC0011E UNABLE TO 3 17/09/11 PI83342 UI50068 1709 HIPER CPSM SECURITY CHECKS ON 2 17/08/31 PI83933 UI49817 1708 HIPER MVSWLM BASE TABLE 1 17/08/16 PI81501 UI49448 1708 HIPER EYUXL0905E ASRA IN WTCL


Installation Information

This section contains changes to the product's Program Directory. 1. YY/MM/DD NO ENTRIES


Documentation Changes

This section outlines major errors in the product's published documentation. 1. YY/MM/DD NO ENTRIES


General Information

This section contains general information, i.e. SYSGEN hints/tips. 1. 17/09/01 Additional Information: Note that if you have an API program that connects to a CMAS that has the fix applied, the API program will received the longer, updated records with the new fields for tables WLMAWORK, WLMAWTOR and WLMAWAOR, if the VERSION specified on the CONNECT command is a release for which the fix was provided for this change. You must update your program to take this into account. For an API program, the CMAS only delivers 'best-so-far' levels of tables. Because this fix is being delivered to CPSM releases 4.1 and later, any CMAS that has the fix applied will deliver the updated records to an API program that does an EXEC CPSM CONNEC using a VERSION of 0410, 0420, 0510, 0520, 0530 or 0540. It does not matter whether the user is actually running the release specified in the CONNECT call, or if they applied the PTF for that release - a CMAS that has the fix applied will assume ANY API program that connects to it can handle the expanded records if the VERSION specifies 0410 or later. This fix is being supplied to CPSM versions 4.1 and later through: - CPSM V4R1M0 - APAR PI60326 , PTF UI45102 - CPSM V4R2M0 - APAR PI60326 , PTF UI45103 - CPSM V5R1M0 - APAR PI60273 , PTF UI45104 - CPSM V5R2M0 - APAR PI60273 , PTF UI45105 - CPSM V5R3M0 - APAR PI60327 , PTF UI45106 - CPSM V5R4M0 - included in the GA release of the product Failure to update API programs to handle the expanded table records will result in length errors on the EXEC CPSM FETCH calls, as indicated by the following response and reason codes RESP(1028) : REAS(1285)


Service Recommendations

8 18/03/26 PROBLEM: (PI94526) CPSM S0C4 ASRA ABEND IN METHOD XDW2 UNDER TRANID XDNR USERS AFFECTED: All CICSPlex SM V5R1M0, V5R2M0, V5R3M0 and V5R4M0 Users RECOMMENDATION: INSTALL UI54649 ON VOLID 1000 (JCI710M) 7 18/03/01 PROBLEM: (PI93834) DEFECT 146636 USERS AFFECTED: All users of CICSPlexSM V5R1M0, V5R2M0, V5R3M0, V5R4M0. RECOMMENDATION: INSTALL UI54089 ON VOLID 1802 (JCI710M) 6 18/02/05 PROBLEM: (PI92852) SHIP CORRECT MAS GENERIC RECEIVER TABLES USERS AFFECTED: All CICSPlex SM V5R3M0 and V5R4M0 Users. RECOMMENDATION: INSTALL UI53571 ON VOLID 1802 (JCI710M) 5 18/02/02 PROBLEM: (PI90941) CPSM WLM ROUTING MAY INCORRECTLY FAVOR SOME AORS WHEN THEY HAVE EQUAL LOADS USERS AFFECTED: All CICSPlex SM V5R1M0, V5R2M0, V5R3M0 and V5R4M0 Users. RECOMMENDATION: INSTALL UI53578 ON VOLID 1801 (JCI710M) 4 17/10/30 PROBLEM: (PI88323) EYUXC0011E UNABLE TO ESTABLISH ACCESS TO DATASPACE XXXXXXXX, ALESERV RC=0000000C USERS AFFECTED: All CICSPlex SM V5R2M0, V5R3M0 and V5R4M0 Users. RECOMMENDATION: INSTALL UI51380 ON VOLID 1710 (JCI710M) 3 17/09/11 PROBLEM: (PI83342) CPSM SECURITY CHECKS ON INCORRECT RESOURCE NAME AFTER PTF APPLIED 17/06/20 PTF PEREMOVE USERS AFFECTED: All CICSPlex SM V5R4M0 Users RECOMMENDATION: INSTALL UI50068 ON VOLID 1709 (JCI710M) 2 17/08/31 PROBLEM: (PI83933) MVSWLM BASE TABLE INCORRECT. USERS AFFECTED: All CICSPlex SM V540 Users RECOMMENDATION: INSTALL UI49817 ON VOLID 1708 (JCI710M) 1 17/08/16 PROBLEM: (PI81501) EYUXL0905E ASRA IN WTCL ABEND0C4 IN GET_WGSC_QUERY ROUTINE USERS AFFECTED: All CICSPlex SM V5R1M0, V5R2M0, V5R3M0 and V5R4M0 Users RECOMMENDATION: INSTALL UI49448 ON VOLID 1708 (JCI710M)


Cross Product Dependencies

This section contains information that is dependent upon another product other than this subset ID. It also contains information dealing with migration and product coexistance. 1. YY/MM/DD INTERDEPENDENT PRODUCT: PROBLEM: USERS AFFECTED: RECOMMENDATION: INSTALL XXXXXXX ON VOLID XXXX


Informational / Documentation


PTF / APAR Reference Lists

PTF Include List
UI54649
PTF Exclude List
PE APAR List


End of Upgrade CICSTS54 , Subset JCI710M , as of 2018/03/27.



Document information

More support for: z/OS family

Modified date: 26 March 2018


Translate this page: