Error description
With APAR VM65926(UV61388) specifying the minimum length NICDEF command returns successfully but is not added to the directory.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All users of DirMaint specifying the miminum * * NICDEF statement. * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: APPLY PTF * **************************************************************** With APAR VM65926 applied, DirMaint will not put a NICDEF statement into the user's directory when the NICDEF is the minimum format of "nicdef <addr> type <type>". DirMaint indicates it performed the function but the NICDEF statement is not added. This occurs due to an error in DVHBBXED. The code parses the minimum info and then loops to process any additional options. As part of that processing it will invoke 'output' to put the new external formatted statement on a pipe. If there is no additional information other than the minimum NICDEF specification, then the 'output' is not performed to put the data on the pipe and the statement is not added to the directory.
Problem conclusion
The loop in DVHBBXED REXX is updated to output the minimum NICDEF specification correctly adding the statement to the user's directory.
Temporary fix
Comments
APAR Information
APAR number
VM66227
Reported component name
IBM DIRMAINT-VM
Reported component ID
5749DVH00
Reported release
640
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-11-15
Closed date
2018-11-27
Last modified date
2019-09-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UV99340 UV99341
Modules/Macros
DVHBBXED
Fix information
Fixed component name
IBM DIRMAINT-VM
Fixed component ID
5749DVH00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG27M","label":"APARs - z\/VM environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Edition":"","Line of Business":{"code":"LOB16","label":"Mainframe HW"}}]