A fix is available
APAR status
Closed as program error.
Error description
GDPS VA requires a SVMR record for PPRC Suspend events when the devices are not enabled for Hyperswap Auto-Quiesce.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All z/VM Hyperswap Users * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: APPLY PTF * **************************************************************** GDPS requires that a SVMR record be built on a Suspend event regardless if the device is enabled for Hyperswap or not.
Problem conclusion
HCPSDV has been modified to always issue a SVMR record when the suspend event occurs.
Temporary fix
FOR RELEASE VM/ESA CP/ESA R540 : PREREQ: VM65816 CO-REQ: NONE IF-REQ: NONE FOR RELEASE VM/ESA CP/ESA R620 : PREREQ: VM65816 CO-REQ: NONE IF-REQ: NONE FOR RELEASE VM/ESA CP/ESA R630 : PREREQ: VM65816 CO-REQ: NONE IF-REQ: NONE
Comments
APAR Information
APAR number
VM65825
Reported component name
VM CP
Reported component ID
568411202
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-04-20
Closed date
2016-05-10
Last modified date
2017-08-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UM34806 UM34807 UM34808
Modules/Macros
HCPSDV
Fix information
Fixed component name
VM CP
Fixed component ID
568411202
Applicable component levels
R540 PSY UM35173
UP17/07/25 I 1000
R620 PSY UM34807
UP16/05/11 I 1000
R630 PSY UM34808
UP16/12/02 P 1602
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG27M","label":"APARs - z\/VM environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Edition":"","Line of Business":{"code":"LOB16","label":"Mainframe HW"}}]
Document Information
Modified date: