IBM Support

PM92425: ABEND0C4 IN IPVSRVSL WHEN TRYING TO CONNECT TO CICS EXPLORER

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When trying to connect to CICS Explorer, ABEND0C4 in module
    IPVSRVSL, function strcpy(char*,const char*) +x'60' due to
    invalid parms being passed.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of the PDTCC Common Server.        *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABENDS0C4 may occur when running the    *
    *                      check connection button from the        *
    *                      Problem Determination Tools preference  *
    *                      form.                                   *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    The PDTCC Common Server was incorrectly setting an internal
    parameter area, possibly leading to an abends0C4.
    

Problem conclusion

  • PDTCC Common Server has been corrected. The check connection
    function will operate as intended.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM92425

  • Reported component name

    ZPDTOOLS CCOMP(

  • Reported component ID

    5655IPV00

  • Reported release

    160

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-07-04

  • Closed date

    2013-08-02

  • Last modified date

    2013-09-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IPVCONFG IPVSRV   IPVSRVRF IPVSRVSL IPV0LVL
    

Fix information

  • Fixed component name

    ZPDTOOLS CCOMP(

  • Fixed component ID

    5655IPV00

Applicable component levels

  • R160 PSY UK96380

       UP13/08/06 P F308

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"160","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: