Error description

  • An ABEND0C4 occurred in module DFSCM7V0 routine CM7VVGR when an
    invalid ECB address (RPLECB) is passed to VTAM module ISTAICI2
    on a CHANGE ENDAFFIN call. The ABEND occurred in an environment
    with VGR active. The invalid address
    was passed to VTAM in R10 and appears in R8 at ABEND. The logs
    show a DFS3201 MAXIMUM SESSIONS REACHED message was issued for
    the MSC link immediately before the ABEND. The output RPL for
    the MSC link is being used to issue the RPLCHNG call, but it has
    not been initialized yet resulting in the ABEND0C4.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS V13 users using MSC VTAM links       *
    *                 and VTAM Generic Resources.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: An ABENDS0C4 occurred in module         *
    *                      DFSCM7V0 routine CM7VVGR due to a       *
    *                      residual value in RPLECB.               *
    *                                                              *
    *                      This is a forward-fit of APAR PM80478.  *
    ****************************************************************
    * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF      *
    ****************************************************************
    An ABEND0C4 occurs in module DFSCM7V0 due to an invalid ECB
    (RPLECB) address.  The problem occurs as follows:
    
    1. A cold MSC session is initiated via a /RST LINK command.
    
    2. Due to maximum sessions reached, a MSGDFS3201 message
       is issued.  As a result of this, DFSCM7A0 does not
       initialize the RPL in the output buffer.  CTB7INIT is not
       set to indicate that the RPL has been initialized.
    
    3. DFSCM7V0 gets control and issues a CHANGE ENDAFFNF request
       to VTAM.  Since the RPL has not been initialized, residual
       data in RPLECB results in the abend.
    

Problem conclusion

  • GEN:
    KEYWORDS:
    
    *** END IMS KEYWORDS ***
    DFSCM7V0 has been modified to run the LXB chain to determine
    if the current LLB exists.  If the LLB exists in the LXB chain,
    RPLECB will be updated with the Send ECB from the LXB.
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PM81764

  • Reported component name

    IMS V13

  • Reported component ID

    5635A0400

  • Reported release

    302

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-01-30

  • Closed date

    2013-02-14

  • Last modified date

    2013-10-04

  • APAR is sysrouted FROM one or more of the following:

    PM80478

  • APAR is sysrouted TO one or more of the following:

    UK91687

Modules/Macros

  •    DFSCM7V0
    

Fix information

  • Fixed component name

    IMS V13

  • Fixed component ID

    5635A0400

Applicable component levels

  • R302 PSY UK91687

       UP13/02/20 P F302 Ž

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"302","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 December 2020