A fix is available
APAR status
Closed as program error.
Error description
ABEND806 for program DFSIVP1 attempting to run the IVTNO transaction. ABEND806 for program DFSIVP7 running multiple IVP jobs like IV_F205J, IV_F207J, IV_F210J, IV_F212J, IV_G210J, ETC. . Job IV_E206J assembles and binds DFSIVP1 and DFSIVP7 multiple times with different ALIAS, this causes message IEW2625I 4401 EXISTING ALIAS xxxxxxx WILL BE DROPPED FROM MODULE xxxxxxxWHEN IT IS REPLACED
Local fix
Run IV_E206J last steps named DFSIVA1/DFSIVA7 with the all ALIAS statements for example: ---------------------------------------------------------------- //DFSIVA1 EXEC PROC=ASSEM1,SRC=DFSIVA1 //L.SYSIN DD * INCLUDE RESLIB(DFSLI000) ENTRY DFSIVA1 ALIAS DFSIVP1 ALIAS DFSIVPD2 NAME DFSIVA1(R) //DFSIVA7 EXEC PROC=ASSEM1,SRC=DFSIVA7 //L.SYSIN DD * INCLUDE RESLIB(DFSLI000) ENTRY DFSIVA7 ALIAS DFSIVP7 ALIAS DFSIVPD3 NAME DFSIVA7(R)
Problem summary
**************************************************************** * USERS AFFECTED: All IMS V12 IVP users * **************************************************************** * PROBLEM DESCRIPTION: ABENDS0806 encountered for program * * DFSIVP1 when attempting to run the * * IVTNO transaction. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** In the IMS IVP, the DFSIVA1 and DFSIVA7 entries are link edited multiple times using different ALIAS statements. During binding the following message may appear: IEW2625I 4401 EXISTING ALIAS xxxxxxx WILL BE DROPPED FROM MODULE xxxxxxx WHEN IT IS REPLACED The process of link editing multiple times, and using different aliases, results in multiple TTRs for the same module which can then cause an ABENDS806-04 when running the IVTNO transaction. The same problem exists with IVP module DFSIVA7 and its related transactions.
Problem conclusion
GEN: KEYWORDS: S806 ABEND806 ABENDS806 ABENDS0806 ABENDS806-04 *** END IMS KEYWORDS *** The following part was changed to correct the problem: DFSIXSE5 The binding statements of the skeleton were corrected depending on the environment: 1. In DBCTL or XRF environments, DFSIVA1 is link edited once with two aliases: DFSIVP1 and DFSIVPD2. 2. In an IMS batch environment, a single alias for DFSIVA7 is created: DFSIVP7. 3. In DB/DC, DBCTL or XRF environments, DFSIVA7 has 2 aliases created: DFSIVP7 and DFSIVPD3.
Temporary fix
Comments
APAR Information
APAR number
PM80002
Reported component name
IMS V12
Reported component ID
5635A0300
Reported release
200
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-01-04
Closed date
2013-02-08
Last modified date
2013-03-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
DFSIXSE5
Fix information
Fixed component name
IMS V12
Fixed component ID
5635A0300
Applicable component levels
R200 PSY UK91528
UP13/02/14 P F302
Fix is available