IBM Support

PM79709: TRANSFER OF LOAD MODULE MEMBER TO A NON-MVS SYSTEM ABENDS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • An attempt to use the FTP client to transfer a member of a load
    module data set to a server on a non-MVS system causes the
    client session to ABEND.
    
       MPUT *
       EZA1701I >>> XLMT PDS 241340
        500 Unknown command, 'XLMT'
       CEE3204S The system detected a protection exception (System
                Completion Code=0C4).
                From entry point diroutp at compile unit offset
                +000006C4 at entry offset +000006C4 at address
                1862AD8C.
       IEA995I SYMPTOM DUMP OUTPUT
          USER COMPLETION CODE=4039 REASON CODE=00000000
    

Local fix

  • Use the FTP client on the non-MVS system to connect to the z/OS
    FTP server and perform the equivalent transfer.
    
    
    
    Other Keywords:
    
       U4039  S0C4  ABENDU4039 ABENDS00C4
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of the IBM Communications Server   *
    *                 for z/OS Version 1 Release(s) 12 and 13      *
    *                 IP: FTP                                      *
    ****************************************************************
    * PROBLEM DESCRIPTION: When attempting to PUT from a load      *
    *                      library to a non-MVS server, an abend   *
    *                      occurs in FTP client with the message   *
    *                      CEE3204S The system detected a          *
    *                               protection exception (System   *
    *                               Completion Code=0C4).          *
    *                               From entry point diroutp at    *
    *                               compile unit offset +000006C4  *
    *                               at entry offset +000006C4 at   *
    *                               address 1862AD8C.              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The root cause is that in function setupXLMT() when the reply
    is 500 which indicates "server does not support load module
    transfer", setupXLMT() should return NOTOK to indicate regular
    processing is to be used instead of load module processing, but
    actually setupXLMT() returns OK to allow load module transfer,
    so it leads to abend.
    +-------------------------------------------------------------+
    + Please check our Communications Server for OS/390 homepages +
    + for common networking tips and fixes.  The URL for these    +
    + homepages can be found in Informational APAR II11334.       +
    +-------------------------------------------------------------+
    

Problem conclusion

Temporary fix

Comments

  • This APAR is being closed FIN (Fixed If Next) with concurrence
    from the submitting customer. This means that a fix to this
    APAR is expected to be delivered from IBM in a release (if any)
    to be available within the next 24 months.
    
    This problem will be tracked as Feature F156185
    by Communications Server for z/OS Development.
    
    The solution for this APAR is included in
    CS for zOS Version 2 Release 1.
    

APAR Information

  • APAR number

    PM79709

  • Reported component name

    TCP/IP V3 MVS

  • Reported component ID

    5655HAL00

  • Reported release

    1C0

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-12-26

  • Closed date

    2013-01-07

  • Last modified date

    2013-09-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • R1C0 PSN

       UP

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1C0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCY4DZ","label":"DO NOT USE"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1C0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
16 September 2013