PM74023: ABEND0C4 IN MODULE DFSCM7A0, DURING LINK RESTART WHEN RPLARG STILL CONTAINS THE CID.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Abend 0c4 in DFSCMA70 near label OPNDST10. The abend is due to
    the fact that RPLARG still contains the old CID instead of a
    NIB pointer. This failure occurs on an IMS system that is
    the remote end of an MSC link whose partern is in the process
    of a TKO. At the same time the link terminates and since
    SONCOS=YES is specified in VTAM, restart recovery is taking
    place for the Link.
      We see the following message on the log just before the
    failure:
    DFS3222I 12:07:38 UNEXPECTED*STATUS ,LINK = 001,******,RC=00,
    FDB2= 00,UNBIND ....= 0F,SENSE=00000000.
      Due to the setting of CTB7INIT during this recovery attempt,
    the RPLARG field was not properly updated with the NIB address.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All V12 IMS users with MSC and SON/COS       *
    *                 (SONSCIP=YES) defined.                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABENDS0C4 in DFSCM7A0, when RPLARG      *
    *                      contains a CID instead of pointing      *
    *                      to a NIB.                               *
    *                                                              *
    *                      This is a forward-fit of APAR PM73190.  *
    ****************************************************************
    * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF      *
    ****************************************************************
    ABENDS0C4 occurs in DFSCM7A0 near label OPNDST10.  The abend is
    due to the fact that RPLARG still contains the old CID instead
    of a NIB pointer.
    
    SON/COS processing depends on CTB7INIT being off so that the RPL
    and NIB can be initialized.  With CTB7INIT not reset during link
    cleanup, RPLARG is not initialized to point to the NIB and
    instead contains the CID from the previous session.  This leads
    to the abend when RPLARG is accessed.
    
    Note:
    To activate SON/COS, SONSCIP=YES is specified in VTAM and
    OPTIONS=(ASR) is specified on the MSPLINK macro for IMS.
    

Problem conclusion

  • GEN:
    POSTREQ PM80478
    KEYWORDS:
    
    *** END IMS KEYWORDS ***
    To prevent the abend, CTB7INIT will be reset during link
    cleanup.
    
    DFSCM7Z0 has been modified to check CTBJCHGA to determine
    if a CHANGE ENDAFFNF call is in progress.
    
    DFSCM7A0 has been modified to check CLBV2RSP to detect that
    the Logon exit has been driven due to a REQSESS command and
    will issue an Opndst.
    
    DFSCM7V0 has been modified to not use CTB7INIT to determine if
    subroutine CM7VVGR needs to be called to handle CHANGE ENDAFFNF
    processing.  CTBJCHGA will be used to detect if a CHANGE
    ENDAFFNF call has been made and SCDC1SDC will be used to ensure
    that a /STA DC has been issued before calling subroutine
    CM7VVGR.
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

  • REPINNED RP13/01/15 (ATXT) TO ADD POSTREQ PM80478 INFO.
    **** PE13/01/15 PTF IN ERROR. SEE APAR PM80478 FOR DESCRIPTION
    ×**** PE13/01/16 FIX IN ERROR. SEE APAR PM80478  FOR DESCRIPTION
    

APAR Information

  • APAR number

    PM74023

  • Reported component name

    IMS V12

  • Reported component ID

    5635A0300

  • Reported release

    202

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-09-29

  • Closed date

    2012-10-11

  • Last modified date

    2013-02-14

  • APAR is sysrouted FROM one or more of the following:

    PM73190

  • APAR is sysrouted TO one or more of the following:

    UK82567

Modules/Macros

  •    DFSCM7A0 DFSCM7V0 DFSCM7Z0
    

Fix information

  • Fixed component name

    IMS V12

  • Fixed component ID

    5635A0300

Applicable component levels

  • R202 PSY UK82567

       UP12/10/16 P F210 Ž

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 December 2020