IBM Support

PM60755: MISCELLANEOUS BUG FIXES

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Miscellaneous bug fixes.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Fault Analyzer Version 11 users.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: 01. Explanations not available for VS   *
    *                          COBOL II messages.                  *
    *                          APAR PM59882                        *
    *                      02. IDILANGX abend S0C4 in              *
    *                          ADD_XREF_ELEM when processing       *
    *                          Enterprise COBOL 4.1 compiler       *
    *                          listing.                            *
    *                          APAR PM60788                        *
    *                      03. The user receives message IDI0113W  *
    *                          when IPV is abended due to RTIMOUT. *
    *                          APAR PM63989                        *
    *                      04. Abend S0C4 when using Fault         *
    *                          Analyzer to analyze a Recovery      *
    *                          Fault Recording (RFR) dump.         *
    *                          APAR PM63994                        *
    *                      05. CICS IVP test 4 from CFA            *
    *                          transaction not selectable when     *
    *                          using Rumba terminal emulator.      *
    *                          APAR PM63991                        *
    *                      06. Fault Analyzer IDI* messages might  *
    *                          be written to a HFS file if stderr  *
    *                          not correctly set to FD2.           *
    *                          APAR PM63995                        *
    *                      07. Fault Analyzer abend S0C4 in BldLX  *
    *                          when processing Enterprise PL/I     *
    *                          abend which had the GONUMBER(SEP)   *
    *                          compiler option in effect.          *
    *                          APAR PM62263                        *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    01. VS COBOL II message explanations missing from the Fault
        Analyzer message repository.
    02. 7-digit LineID used in source and data xref sections.
    03. IDIXIPV issues message IDI0113W for all errors, including
        this trivial problem.
    04. The RFR conditions might set an environment where a Fault
        Analyzer internal buffer is exceeded, causing an overlay and
        abend S0C4 in Fault Analyzer.
    05. The attribute used on the panel was acceptable by IBM PCOMMS
        but not with Rumba.
    06. If a job is using HFS files but not running under a Shell
        (such as BPXBATCH) or OMVS, then the Unix File Descriptor 2
        might not have been set to stderr and WTO messages meant for
        stderr might be written to an incorrect HFS file.
    07. Incorrect fixup and processing of multiple sections in
        statement number table.
    

Problem conclusion

  • 01. VS COBOL II message explanations have been added to the
        Fault Analyzer message repository.
    02. IDILANGX now accommodates the 7-digit LineID in source and
        data xref sections.
    03. IDIXIPV has been changed to suppress IDI0113W in the
        RTIMOUT situation.
    04. The buffer pointer position has been correctly set when
        the RFR input only had the invocation exit buffer.
    05. The attribute has been changed to allow correct operation on
        both emulators.
    06. If Unix dubbed and the LE stderr(MSGFILE) file pointer does
        not have FD2 assigned, then the write of IDI* messages will
        not be directed to FD2 stderr.
    07. Fixup and processing of multiple sections in statement
        number table corrected.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM60755

  • Reported component name

    FAULT ANALYZER

  • Reported component ID

    5655W4600

  • Reported release

    B10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-03-19

  • Closed date

    2012-05-07

  • Last modified date

    2012-06-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK78540

Modules/Macros

  • IDICAASM IDICABND IDICALE  IDICALOC IDICASUB
    IDICCFND IDICISA  IDICNOTR IDICOPYR IDICSV13 IDICSV14 IDIDA
    
    ***This field was truncated.  To obtain the full apar record, please contact your local support center.***
    

Fix information

  • Fixed component name

    FAULT ANALYZER

  • Fixed component ID

    5655W4600

Applicable component levels

  • RB10 PSY UK78540

       UP12/05/10 P F205

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B10","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
03 June 2012