A fix is available
APAR status
Closed as program error.
Error description
When running an OLR, an AWE is gotten. The AWE storage is not freed at OLR termination, causing CSA orphaned storage.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS V12 HALDB Online Reorganization * * ( OLR ) users. * **************************************************************** * PROBLEM DESCRIPTION: CSA storage gotten and used as an AWE * * during INIT OLR command processing is * * not freed and is left orphaned after * * the DFSSQPP enqueue of the AWE to * * DFSCST00 to process the command. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** When the INITIATE ( INIT ) OLR command is issued, CSA storage is gotten for an AWE to be used to enqueue the command to DFSCST00. After the command / AWE is enqueued by DFSSQPP, the AWE storage is never freed and is left orphaned.
Problem conclusion
GEN: POSTREQ PM72331 KEYWORDS: *** END IMS KEYWORDS *** The following module has been modified to correct the reported problem: ************ * DFSORC00 * ************ The DFSSQPP enqueue call has been modified to add the FREE= parameter in order that the AWE storage is freed after the INITIATE OLR command has been processed.
Temporary fix
Comments
REPINNED RP13/01/24 (ATXT) TO ADD POSTREQ PM72331 INFO. **** PE13/01/24 PTF IN ERROR. SEE APAR PM72331 FOR DESCRIPTION ×**** PE13/01/24 FIX IN ERROR. SEE APAR PM72331 FOR DESCRIPTION
APAR Information
APAR number
PM57827
Reported component name
IMS V12
Reported component ID
5635A0300
Reported release
200
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-02-09
Closed date
2012-03-01
Last modified date
2013-02-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK76743
Modules/Macros
DFSORC00
Fix information
Fixed component name
IMS V12
Fixed component ID
5635A0300
Applicable component levels
R200 PSY UK76743
UP12/03/03 P F203
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Line of Business":{"code":"","label":""}}]
Document Information
Modified date: