A fix is available
APAR status
-
Closed as program error.
Error description
-
Program EZACIC20 was called via EXEC CICS LINK to stop the CICS sockets interface. The COMMAREA parameter P20TYPE was specified as 'Q' (query the PLT shutdown immediate configuration setting). The call was rejected with a return value indicating an error in COMMAREA contents.
Local fix
-
Specify P20TYPE value of I or D or set PLTSDI to yes
Problem summary
-
**************************************************************** * USERS AFFECTED: All users of the IBM Communications Server * * for z/OS Version 1 Releases 10, 11 and 12 * * IP: CICS Sockets * **************************************************************** * PROBLEM DESCRIPTION: A program link call to EZACIC20 is * * rejected when the value Q is specified * * for the P20TYPE parameter. * **************************************************************** * RECOMMENDATION: * **************************************************************** Program EZACIC20 was called via EXEC CICS LINK to stop the CICS sockets interface. The calling program set the P20TYPE parameter in the COMMAREA section to a value of 'Q' which represents: Query the PLT shutdown immediate configuration option EZACIC20 rejected the call and set the response field P20RET to the value P20RETCA: Error in COMMAREA Contents +-------------------------------------------------------------+ + Please check our Communications Server for OS/390 homepages + + for common networking tips and fixes. The URL for these + + homepages can be found in Informational APAR II11334. + +-------------------------------------------------------------+
Problem conclusion
-
Module EZACIC20 has been amended to allow for a value of Q when performing validity checking on the P20TYPE parameter. * Cross Reference between External and Internal Names
Temporary fix
Comments
APAR Information
-
APAR number
PM35682
-
Reported component name
TCP/IP V3 MVS
-
Reported component ID
5655HAL00
-
Reported release
1B0
-
Status
CLOSED PER
-
PE
NoPE
-
HIPER
NoHIPER
-
Special Attention
NoSpecatt / Xsystem
-
Submitted date
2011-03-25
-
Closed date
2011-04-26
-
Last modified date
2011-07-05
-
APAR is sysrouted FROM one or more of the following:
-
APAR is sysrouted TO one or more of the following:
UK67110 UK67111 UK67112 PM37961
Modules/Macros
-
EZACIC20
Fix information
-
Fixed component name
TCP/IP V3 MVS
-
Fixed component ID
5655HAL00
Applicable component levels
-
R1A0 PSY UK67110
UP11/06/21 P F106
-
R1B0 PSY UK67111
UP11/06/21 P F106
-
R1C0 PSY UK67112
UP11/06/21 P F106
Fix is available
-
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSSN3L","label":"z\/OS Communications Server"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"1B0","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: