IBM Support

PK63113: ABENDS0C4 WHEN THE ICEIN CONTROL STATEMENT IS MORE THAN 253 LINES. OCCURS AFTER APPLYING PK45121.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABENDS0C4 occurred after applying PK45121.  This happens when
    the ICEIN control statement is more than 253 lines.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 4 Release 1 users ( FMID=H1J0410 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: After applying APAR PK45121, HPIC Image *
    *                      Copy function terminates with ABEND     *
    *                      S0C4 ( ABEND0C4 ) at FABJMAIN CSECT     *
    *                      FABJPARM + X'6554', if specified        *
    *                      control statements on ICEIN DD are more *
    *                      than 230 lines.                         *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    After applying APAR PK45121, HPIC Image Copy function terminates
    with ABEND S0C4 ( ABEND0C4 ) at FABJMAIN CSECT FABJPARM +
    X'6554', if specified control statements on ICEIN DD are more
    than 230 lines.
    
    By APAR PK45121, HPIC getmain buffer storage in which HPIC keeps
    the ICEIN control statements for ITKB report. But the storage
    estimation is not large enough to keeping 230 lines of control
    statements. Therefore HPIC overwrites data into other HPIC's
    control blocks and terminates with ABEND.
    

Problem conclusion

  • FABURPTH has been modified to getmain a new storage if the line
    counter is over the max number of lines.
    
    FABJPARM, FABJPRM2, FABJRPT1 and FABJGLRP have been modified to
    initialize the header record of the ITKB buffer for keeping the
    report lines.
    
    FABJMAIN, FABJINT1 and FABJCRC0 have been modified to call ITKB
    FUNC=WRITE until the line counter is zero.
    
    FABURHT has been modified to generate the DSECT which is used
    for the header record of the ITKB buffer.
    
    The following modules have been reassembled.
      FABJRPTH FABJDDIM FABJPRM3 FABJRETC
      FABJRETM FABJRPT0 FABJTGEN
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK63113

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-03-21

  • Closed date

    2008-04-01

  • Last modified date

    2008-05-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK35115

Modules/Macros

  • FABJCRC0 FABJDDIM FABJGLRP FABJINT1 FABJMAIN
    FABJPARM FABJPRM2 FABJPRM3 FABJRETC FABJRETM FABJRPTH FABJRPT0
    FABJRPT1 FABJTGEN FABURHT  FABURPTH
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R410 PSY UK35115

       UP08/04/02 P F804 Ø

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"4.1.0","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 December 2020