A fix is available
APAR status
Closed as program error.
Error description
PDTCC LANGX LANGP MISCELLANEOUS BUG FIXES
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All PDTCC LANGX Users. * **************************************************************** * PROBLEM DESCRIPTION: 01. Debug Tools issues EQA9999E * * (Invalid hook address) when * * stepping through assembler code * * that contains internal macro * * comments (.*). * * APAR PI75580 * * * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** 01. LANGX interprets internal macro comments as executable code.
Problem conclusion
01. LANGX now interprets internal macro comments as 'no code' comments.
Temporary fix
Comments
APAR Information
APAR number
PI77004
Reported component name
ZPDTOOLS CCOMP(
Reported component ID
5655IPV00
Reported release
170
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-02-22
Closed date
2017-03-29
Last modified date
2017-05-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI45979 UI45980
Modules/Macros
IPVEPRCV IPVEPSND IPVLANGO IPVLANGP IPVLANGX IPVLANGZ IPV0LVL
Fix information
Fixed component name
ZPDTOOLS CCOMP(
Fixed component ID
5655IPV00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"170","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
01 May 2017