A fix is available
APAR status
Closed as program error.
Error description
An ABEND occurs in Telnet modules upon return from VTAM due to the high word of a register being cleared.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of the IBM Communications Server * * for z/OS Version 2 Release 2 IP: Telnet * * Server * **************************************************************** * PROBLEM DESCRIPTION: * * ABEND0C4 in various Telnet modules * **************************************************************** * RECOMMENDATION: * * Apply PTF * **************************************************************** The problem may be summarized as follows: 1. A session is established through Telnet to a VTAM application. 2. Data is sent on the session. 3. ABEND0C4 occurs in either EZBTVSRP, EZBTVXRC, or EZBTVXS2 due to the high word in a register being 0.
Problem conclusion
Telnet is modified to save and restore the high words of registers.
Temporary fix
Comments
APAR Information
APAR number
PI57735
Reported component name
TCP/IP V3 MVS
Reported component ID
5655HAL00
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-02-22
Closed date
2016-02-25
Last modified date
2016-05-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI35655
Modules/Macros
EZBTVSRP EZBTVXS2 EZBTVXRC
Fix information
Fixed component name
TCP/IP V3 MVS
Fixed component ID
5655HAL00
Applicable component levels
R220 PSY UI35655
UP16/04/07 P F604
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCY4DZ","label":"DO NOT USE"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: