Error description

  • New Function
    WLM Importance Based Initiator Dispatching Priority Control
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of OS/390 R10 (HBB7703) and above      *
    ****************************************************************
    * PROBLEM DESCRIPTION: When running in compatibility mode,     *
    *                      initiators are assigned the dispatching *
    *                      priority that is specified by the       *
    *                      PVLDP keyword in the IEAIPSxx parmlib   *
    *                      member. In goal mode, initiators run    *
    *                      in service class SYSSTC with a fixed    *
    *                      dispatching priority of 254 and there   *
    *                      is no way to adjust or change the       *
    *                      dispatching priority. The work running  *
    *                      under the initiator is assigned its     *
    *                      installation specified service class    *
    *                      during SYSEVENT JOBSELCT processing.    *
    *                      If there are cpu intensive exits that   *
    *                      run prior to job select processing, the *
    *                      work will run at dispatching priority   *
    *                      254 and this can potentially impact     *
    *                      high importance work.                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When running in goal mode, there may be rare cases where it is
    necessary to be able to adjust the dispatching priority of
    initiators so that cpu intensive exits running prior to job
    select do not impact high importance work.
    

Problem conclusion

Temporary fix

Comments

  • A new parameter INITIMP in the IEAOPTxx member of SYS1.PARMLIB
    has been defined to allow an installation to set the initiator
    dispatching priority. The new dispatching priority applies to
    JES, APPC and OMVS initiators.
    Parameter INITIMP can be set as follows:
    - INITIMP=0
      is the same as if the parameter hasn't been defined.
      The initiator dispatching priority is set to 254.
    - INITIMP=1,2, or 3
      defines that the initiator dispatching priority has to be
      lower than the dispatching priority for cpu critical work
      with the same or a higher importance level.
      If no service class with the cpu critical attribute and a
      corresponding or higher importance level is defined in the
      WLM policy, the dispatching priority is calculated in the
      same way as for parameter INITIMP=E.
    - INITIMP=E
      defines that the initiator dispatching priority will be
      calculated in the same way as the enqueue promotion
      dispatching priority. The dispatching priority is calculated
      dynamically to ensure access to the processor. It should not
      impact high importance work, however there is no guarantee
      that cpu critical work will always have a higher dispatching
      priority.
    
    The default is INITIMP=0. So if the INITIMP parameter is not
    defined or if it is defined as INITIMP=0, all JES, APPC and OMVS
    initiators will run at dispatching priority 254 as they
    currently do today, ensuring that the current system behavior
    remains unchanged. Therefore, no  changes or updates to the OPT
    are necessary unless your installation requires the dynamic
    calculation of the initiator dispatching priority.
    
    If your installation requires the dynamic calculation of the
    initiator dispatching priority, you will need to specify the new
    parameter INITIMP in the IEAOPTxx member of SYS1.PARMLIB
    When specifying an INITIMP value, it will only affect the system
    it has been set on. You can activate a new OPT parmlib member
    with the SET command: SET OPT=xx.
    After specifying an INITIMP value,the initiator will still show
    a service class of SYSSTC but the dispatching priority will be
    based on the INITIMP setting.
     **** PE03/06/03 FIX IN ERROR. SEE APAR OA03581  FOR DESCRIPTION
    

APAR Information

  • APAR number

    OW55344

  • Reported component name

    WORK LOAD MANAG

  • Reported component ID

    5752SCWLM

  • Reported release

    705

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2002-06-25

  • Closed date

    2003-02-28

  • Last modified date

    2003-07-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA01312 UA01313 UA01314 UA01315 UA01318

Modules/Macros

  •    IEAVNP10 IEEMB812 IRACPUDP IRAEVREQ IRAOLST
    IRAPAPPP IRARMCTY IRARMEVT IRARMOPT IRARMSOP IRASETNP JBB7713J
    

Publications Referenced
SA22759200    

Fix information

  • Fixed component name

    5752 SYS RSRCE

  • Fixed component ID

    5752SC1CX

Applicable component levels

  • R703 PSY UA01312

       UP03/04/05 P F304

  • R705 PSY UA01313

       UP03/03/19 P F304

  • R706 PSY UA01314

       UP03/03/19 P F304

  • R707 PSY UA01315

       UP03/03/19 P F304

  • R713 PSY UA01318

       UP03/04/05 P F304

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

Copyright and trademark information

IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.

Rate this page

Please take a moment to complete this form to help us better serve you.

This material provides me with the information I need.






This material is clear and easy to understand.






Did the information help you to achieve your goal?

What updates, improvements, or related information would you like to see in this document?

Your response will be used to improve our document content. Requests for assistance, if applicable, should be submitted through your normal support channel as we cannot respond from this site.


Input the verification number to submit feedback:



Maintenance Window

Unscheduled Maintenance Window

There is no unscheduled maintenance scheduled at this time.

Document information

Product categories:

Software

Operating System

z/OS family

APARs - z/OS environment


Operating system(s):

MVS, z/OS


Software version:

705


Reference #:

OW55344


IBM Group:

IBM Server Group


Modified date:

2003-07-10

Translate my page