Error description

  • New Function
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IOCP users requiring support for the         *
    *                 D/T3931 IBM z16 model A01 server and the     *
    *                 IBM LinuxONE Emperor 4 model LA1.            *
    ****************************************************************
    * PROBLEM DESCRIPTION: IOCP New Function                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This PTF introduces a new release of ICP IOCP and is
    VERSION 6 RELEASE 1 LEVEL 0 (6.1.0) of the program.  ICP IOCP
    supports the IBM z16 3931 model A01 and IBM LinuxONE Emperor 4
    model LA1.
    

Problem conclusion

  • *
    ICP IOCP VERSION 6 RELEASE 1 LEVEL 0 (6.1.0) provides the
    following support:
      - The 3931 models (A01 and LA1) are supported with
        SYSTEM=(3931,1).
        IOCP ignores the MAXDEV keyword on the RESOURCE statement
        and reserves the maximum number of devices for these models.
        Also, IOCP reserves the maximum number of channel
        subsystems (CSSs) and logical partitions for these models.
      - IOCP continues to use a variable amount of storage based
        on the type of IOCDS it is processing.  IOCP requires 215MB
        for the 3931 central processor complex (CPC).
      - The MCS_1 firmware partition cannot be defined on the 3931
        CPC and IOCP rejects its specification.  The functionality
        MCS_1 provided is always present on a 3931 CPC and it does
        not need to be defined.
      - IOCP now supports virtual storage above the 2GB bar for
        which the storage size is specified in the MEMLIMIT
        parameter of a JOB statement.  Instead of MEMLIMIT, you can
        continue to use the REGION parameter of the JOB statement in
        which case IOCP uses storage below the 2GB bar.
      - IOCP now accepts blank lines in its source input.
      - FMID HIO1105 for z/OS V2R5 drops support for the following
        CPCs:  2084, 2086, 2094, 2096, 2097, and 2098.  FMID HIO1104
        continues to support these CPCs.
      - The 3931 CPC does not support the mixing of FC and FCP CHPID
        types on a FICON adapter with or without the MIXTYPE
        keyword.  Defining a mix of channel path types results in
        the following error message:
    
        ICP374I  INVALID MIX OF CHPID TYPES FOR PCHIDS xxx AND yyy
    
        To correct the error, change one of the channel path types
        so that the PCHIDs have the same channel path type.
    *
    *
    Documentation Changes:
    There is a new publication "Input/Output Configuration
    Program User's Guide for ICP IOCP" which has order number
    SB10-7177-00.  The publication is available using Resource
    Link at http://www.ibm.com/servers/resourcelink by selecting
    section:
    Library > IBM z16 A01
    Library > LinuxONE Emperor 4 LA1
    *
    EC (Engineering Change) Information:
    This PTF level of ICP IOCP contains support for IBM z16
    and LinuxONE Emperor 4 central processor complexes (CPCs).
    See Usage Notes for further information.
    *
    Information on equivalent STAND-ALONE IOCP, z/OS IOCP, z/VM
    IOCP, and z/VSE IOCP follows:
    *
    *
      - Equivalent STAND-ALONE IOCP for ICP IOCP version 6.1.0 is
        in the listed EC's.  The EC's listed are the first levels
        shipped with this release of IOCP.
            EC       MACHINE TYPE
          P30763         3931
    *
      - Equivalent z/OS, z/VM, and VSE IOCP is shipped via the
        listed APARs.
          OPERATING SYSTEM       APAR
               z/OS            OA60286
               z/VM            VM66549
               z/VSE           DY47850
    *
    *
    The EC level of the CPC can be determined from the Hardware
    Management Console or Support Element by doing the following:
      1. From Navigation pane, select 'Systems Management' on
         HMC or 'System Management' on Support Element.
      2. Select 'Systems' on HMC.
      3. Select the CPC you are interested in.
      4. Expand the 'Change Management' tasks area.
      5. Open 'System Information' in the 'Change Management'
         tasks area and look for Description 'Input/Output
         Configuration Program' to identify the appropriate EC
         level.
    *
    The STAND-ALONE IOCP version and release can be determined by
    looking at the header lines of the IOCP reports produced by
    STAND-ALONE IOCP.  The STAND-ALONE IOCP version and release can
    also be found in IOCP message ICP073I in an I/O Configuration
    Source file that was processed by STAND-ALONE IOCP.  The
    STAND-ALONE IOCP version and release can also be determined
    from the Hardware Management Console or Support Element by
    doing the following (begin with step 6 for the Support Element
    Console):
      1. Select 'Systems Management' from Navigation pane.
      2. Select 'Systems'.
      3. Select the CPC you are interested in.
      4. Expand the 'Recovery' tasks area.
      5. Open 'Single Object Operations' in the 'Recovery'
         tasks area to connect to the Support Element.
      6. Select 'System Management' from Navigation pane.
      7. Select the CPC or an activated partition.  (Note that
         an activated partition is required to write an IOCDS.)
      8. Expand 'Configuration' from the tasks area.
      9. Open 'Input/output (I/O) Configuration' in the
         'Configuration' tasks area.
      10. Select 'View' pull-down.
      11. Select 'Configuration Program Level'.
    *
    Usage Notes:
    1. If you are currently using a release of ICP IOCP and you do
       not plan on upgrading to the listed EC level, you can
       still install this PTF and replace your existing ICP IOCP.
       The 2817, 2818, 2827, 2828, 2964, 2965, 3906, 3907, 8561,
       and 8562 models can power-on reset with an IOCDS written by
       the ICP IOCP shipped by this PTF.  Also, the 2817, 2818,
       2827, 2828, 2964, 2965, 3906, 3907, 8561, and 8562 models can
       still power-on reset with an IOCDS that was written by your
       previous release of ICP IOCP.  There is no requirement that
       you write an IOCDS with the ICP IOCP shipped by this PTF and
       perform a power-on reset after the PTF has been installed.
    2. Any IOCDS previously created by an ICP version of IOCP
       (z/OS, VM, VSE, or STAND-ALONE) can be reported on by the
       ICP version of IOCP shipped by this PTF.
    3. Any IOCDS previously created by another version of IOCP
       (e.g. IYP IOCP) cannot be reported on by the ICP version of
       IOCP shipped by this PTF or by the STAND-ALONE equivalent
       version of the ICP IOCP program.  (For HCD users, HCD manages
       the correlation of IOCP versions to CPC model for you.)
    4. If you are upgrading to a 3931 model, you MUST write a 3931
       IOCDS to your current 3906 or 8561 CPC as described here or
       write a 3931 IOCDS after the upgrade is completed.  Prior
       to the upgrade, use IOCP execution parameter
       CHECKCPC=NO or HCD option
       'Write IOCDS in preparation of upgrade'.  The IOCDS will be
       unusable until your CPC has been upgraded to a 3931.
       Inform the installing service representative that you have
       pre-written a 3931 IOCDS and which IOCDS should be
       selected after the upgrade.
    5. Although FMID HIO1104 also includes support for
       IXPIOCP (3090, 9021, 9121, and 9221 only), IZPIOCP (2003,
       3000, 7060, 9021, 9121, 9672, and 9674 only), and IYPIOCP
       (2064 and 2066), these programs are not affected by this
       PTF.  Program IOPIOCP (3090 only) will be reused at some
       point in the future for a new processor.
    
    KEYWORDS: R3931/K
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA60286

  • Reported component name

    IOCP COMMON

  • Reported component ID

    566529101

  • Reported release

    104

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / CST /

  •  

    Xsystem

  • Submitted date

    2020-10-01

  • Closed date

    2022-03-08

  • Last modified date

    2022-09-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ07913 UJ07914

Modules/Macros

  • ICPCARDF ICPCARDS ICPCARDU ICPCARDW ICPCARDX ICPCARDY ICPCARDZ
    ICPCFRST ICPCGET  ICPCGNDS ICPCINIT ICPCIOCP ICPCIOCU ICPCIODV
    ICPCMSG  ICPCPCHK ICPCPUT  ICPCRDDS ICPCRPT  ICPCRPTA ICPCRPTF
    ICPCRPTX ICPCRTNS ICPCRTNX ICPCWTDS ICPL1104 ICPL1105 ICPPCNTL
    ICPPMVS
    

Publications Referenced
SB10717700    

Fix information

  • Fixed component name

    IOCP COMMON

  • Fixed component ID

    566529101

Applicable component levels

  • R104 PSY UJ07914

       UP22/04/05 P F204  

  • R105 PSY UJ07913

       UP22/04/05 P F204  

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"104"}]

Document Information

Modified date:
13 September 2022