A fix is available
APAR status
Closed as program error.
Error description
When attempting to use the new KEYLABEL or ENCRYPTKEY operands of the SSIGNON segment, the following error message will be generated. IKJ56702I INVALID OPERAND, ÝKEYLABEL | ENCRYPTKEY¨ This problem only affects installations which exploit the KEYLABEL and ENCRYPTKEY keywords in the SSIGNON segment in RALTER and RDEFINE commands. USER'S AFFECTED: Users who have installed APAR OA55926, PTF UA99803 for HRF77BO and are using the new KEYLABEL and ENCRYPTKEY operands of the SSIGNON segment in RALTER and RDEFINE commands. USER IMPACT: APAR OA55926 fixed the problem it reported, but it introduced a new problem. Support was added for MFA enhancements. It introduced a new problem when RALTER and RDEFINE commands are invoked with the new KEYLABEL and ENCRYPTKEY operands of the SSIGNON segment. The customer will start receiving messages IKJ56702I because the new KEYLABEL and ENCRYPTKEY operands of SSIGNON were erroneously removed from the Dynamic Parse Specification Table. IBM recommends to keep the PTFs installed, unless the KEYLABEL and ENCRYPTKEY operands are needed in RALTER and RDEFINE commands.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * RACF installations that define or alter PassTicket keys. * **************************************************************** * PROBLEM DESCRIPTION: * * The RACF Dynamic Parse Specification Data Set (IRRDPSDS) was * * incorrectly updated by OA55926 in HRF77B0 to remove the * * SSIGNON segment keywords KEYLABEL and ENCRYPTKEY introduced * * by OA56831. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The RACF Dynamic Parse Specification Data Set (IRRDPSDS) is updated to restore the KEYLABEL and ENCRYPTKEY keywords to the SSIGNON segment as introduced by OA56831 in HRF77B0. This update restores the ability to use these keywords in the RDEFINE and RALTER commands.
Temporary fix
Comments
APAR Information
APAR number
OA58083
Reported component name
RACF
Reported component ID
5752XXH00
Reported release
7B0
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-08-01
Closed date
2019-09-10
Last modified date
2019-10-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ00788
Modules/Macros
IRRDPSDS
Fix information
Fixed component name
RACF
Fixed component ID
5752XXH00
Applicable component levels
R7B0 PSY UJ00788
UP19/09/25 P F909 {
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7B0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7B0","Edition":"","Line of Business":{"code":"","label":""}}]