IBM Support

OA53620: CBR9232I SURFACED DURING OSMC PROCESSING.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • CBR9232I message surfaced during OSMC processing due to the
    ODSCNUM and ODMCNUM being set to zero in the object directory
    table when an object is stored.
    
    *** VERIFICATION:
    SELECT * FROM hlq.OSM_OBJ_DIR;
    **where hlq is the DB2 identifier for the particular object
    storage group
    
    KEYWORDS: OAM ODSCNUM ODMCNUM CBR9232I
    

Local fix

  • Determine what the correct ODSCNUM and ODMCNUM values are for
    each of the objects. Use SPUFI to update the object directory
    table (OSM_OBJ_DIR) with the correct IDs.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * OAM object support users with APAR OA51129                   *
    * applied.                                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Un-initialized pointer causes                                *
    * unpredictable MC/SC ID behavior.                             *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Pointer initialized and MC/SC ID predictability restored.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA53620

  • Reported component name

    OBJECT ACCESS M

  • Reported component ID

    5695DF180

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-08-04

  • Closed date

    2017-10-04

  • Last modified date

    2021-11-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA93821 UA93822 UA93823

Modules/Macros

  • CBRHSMSI
    

Fix information

  • Fixed component name

    OBJECT ACCESS M

  • Fixed component ID

    5695DF180

Applicable component levels

  • R210 PSY UA93822

       UP17/10/17 P F710 {

  • R220 PSY UA93823

       UP17/10/17 P F710 {

  • R230 PSY UA93821

       UP17/10/17 P F710 {

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.