A fix is available
APAR status
Closed as new function.
Error description
XES Lock Dataspaces Constraint Relief.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Installations exploiting parallel sysplex using lock or * * serialized list structures at z/OS V2R3 (HBB77B0). * **************************************************************** * PROBLEM DESCRIPTION: * * New function is required to relieve constraints affecting * * the maximum number of connectors to lock or serialized list * * structures from a single address space. * * * * SYSPLEXDS * **************************************************************** * RECOMMENDATION: * * Install the applicable PTF on each system in the sysplex. * * A rolling IPL is sufficient to activate the fix. * **************************************************************** Connections to lock and serialized list structures have always used data spaces to contain control blocks related to processing of end-user requests. z/OS V1R7 (HBB7720) introduced additional data spaces for lock structures to relieve constraints on the number of requests that could be in progress simultaneously. It was known that this would constrain the number of connections to a structure from a single address space, which was an acceptable trade-off at that time. However, that limitation has since become more of a concern, and new function is now required to relieve that constraint.
Problem conclusion
Temporary fix
Comments
Eliminated the use of connector-related data spaces by moving applicable control blocks above the 2G bar. This greatly reduces the number of PASN-AL slots consumed by serialized connectors, relieving the constraint on the number of connectors from a given address space. Documentation updates: PUBLICATIONS AFFECTED z/OS MVS Programming: Sysplex Services Reference SA38-0658 Chapter "IXLCONN - Connect to a Coupling Facility Structure" Section "Restrictions" In the bullet beginning "The maximum number of connections to a structure in the coupling facility depends on:", delete the subordinate bullet "The address space limit of 128 PASN-AL entries for serialized structures per address space. (The lock structure and the serialized list structure are serialized structures.)" Section "Return and Reason Codes" Deleted the following reason codes: o IxlRsnCodeMaxConnectAS (xxxx0C15) o IxlRsnCodePASNExceeded (xxxx0C16) Deprecated the following reason code: o IxlRsnCodeDSNotCreated (xxxx0C12) Defined the following new reason code: o IxlRsnCodeConnStgNotAvail (xxxx0C12, replaces IxlRsnCodeDSNotCreated) PUBLICATIONS AFFECTED z/OS MVS System Messages, Vol 10 (IXC-IZP) SA38-0677 IXL013I requesttype REQUEST FOR STRUCTURE structure-name FAILED Deleted the following errortype inserts: THE MAXIMUM NUMBER OF CONNECTORS IN THIS ADDRESS SPACE EXIST FAILURE ADDING ENTRY TO PASN ACCESS LIST FAILURE CREATING DATA SPACE Added the following new errortype insert: UNABLE TO ASSIGN CONNECTOR STORAGE PUBLICATIONS AFFECTED z/OS MVS Dump Output Messages SA23-1378 IXL0016I Probable queue error detected, queue ID: X'iiiiiiii' | VSA and ALET: nnnnnnnn_nnnnnnnn xxxxxxxx Explanation: IPCS detected a possible problem with an XES queue. In the message text: iiiiiiii | Identifies the failing queue. nnnnnnnn_nnnnnnnn | Virtual storage address of the failing queue header. xxxxxxxx | ALET associated with the failing queue. System action: The system continues processing the IPCS XESDATA subcommand. Source: Cross-system extended services (XES). PUBLICATIONS AFFECTED z/OS MVS System Codes SA38-0665 In the section describing ABEND026, update the "Operator Response" section as follows: | Operator response: Any reason codes not explicitly described | above, including but not limited to those in the following | list, represent errors internal to the XES component. Search problem reporting databases for a fix for the problem. If no fix exists, contact the IBM Support Center.
APAR Information
APAR number
OA53037
Reported component name
CROSS SYS.EXT.S
Reported component ID
5752SCIXL
Reported release
7B0
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / SYSPLXDS /
Xsystem
Submitted date
2017-06-05
Closed date
2017-12-13
Last modified date
2018-01-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA94775
Modules/Macros
IXLS1REC IXLX1AEI IXLF1VGM IXLF1VGL IXLF1VGT IXLF1VGR IXLF1VGH IXLS1QV IXLF1VGA IXLF1SI2 IXCF1VCC IXLR1DIA IXLR1LKR IXLF1TX2 IXLS1POB IXLX1CNF IXLM1DMP IXLR1NLA IXLR1SUS IXLR2LSD IXLR2LSF IXLX1CNP IXLF1VWR IXLD1INT IXLS1POS IXLF1TF4 IXLF1TF5 IXLF1TF2 IXLF1TF3 IXLM1RMT IXLF1TF6 IXLF1VVT IXLI1SIN IXLM2MR IXLF1TF1 IXLS1TMR IXLF1SIG IXLX1ASR IXLR2CHS IXLX1ASO IXLR2QUE IXLF1TFT IXLS1QUE IXLM1MS2 IXLD1ALC IXLF1RES IXLD1FRE IXLR1LPT IXLF1DEL IXLR1NGM IXLR1RRS IXLR1RCK IXLR1SRB IXLR1QRY IXLR1CMP IXLM2XSR IXLR1RRE IXLR1RCS IXLF1VLM IXLF1VLL IXLM2DRL IXLM2XRQ IXLF1VLH IXLF1VLC IXLR2MPR IXLR1LNT IXLR1LNX IXLR1GLC IXLR1NEI IXLR2MAN IXLR1GLB IXLM1E64 IXLR1GLU IXLE1RDV IXLC2LBF IXLR1RSU IXLR1RSM IXLE1RTY IXLR1ADS IXLF1LCR IXLM1EDD IXCI2PH1 IXLF1TRC IXLM1DDD IXLF1ACC IXLC2RCD IXLF1ARQ IXLR1CAC IXLM2SR IXLR1LSI IXLD1EVR IXLR1QVG IXLQ1EV3 IXLR1ESC IXLC1DCN IXLF1TOR IXLF1VAW IXLM2DR IXLR1GRN IXLR1QVS IXLD1GET IXLR1LST IXLR1GRT IXLC1BLD IXLI1LPX IXLR1PAL IXLR1LCR IXLQ1EVR IXLR1LCK IXLS1FRE IXLM2LRS IXLD1RET IXLS1RNP IXLF1VMA IXLR1RDV IXLS1SSD IXLD2LOC IXLF1VME IXLR1CRR IXLF1VMH IXLM2DSP IXLF1VML IXLF1VDR IXLF1VDS IXLF1VCX IXLR1FCP IXLF1VMR IXLE1MEV IXLR1SIG IXLF1VMT IXLM2TAM IXLF1VDE IXLYCON IXLS1SSP IXLR2PLA IXLF1VCL IXLF1VCN IXLM1TMR IXLF1VCR IXLR1RES IXLS1HTP IXLS1FL IXLLOCK IXLM2CR IXLF1MON IXLM1REC IXLF1FAT IXLR1LRR IXLF1FAX IXLR1LRS IXLF1VST IXLR1CEI IXLF1VSM IXLF1VSO IXLF1VSL IXLF1VSG IXLR1ALR IXLR1BUN IXLR1DES IXLR1ALT IXLF1NAM IXLF1VSU IXLF1VSW IXLF1CON IXLC3DSN IXLR2SSF IXLF1VTL IXLR2SSD IXLR1QV IXLR1RT IXLF1STK IXLR1SYN IXLM2BRK IXLC1CON IXLM1SAD IXLR2QV IXLCONN IXLF1VRB IXLF1VRC IXLC3SCN IXLX1RES IXLM1D64 IXLF1VRN IXLM1TBL IXLF1VRL IXLD1QCR IXLR1UNL IXLC1EOT IXLC1CO1 IXLX1EEI IXLF1LKM IXLF1VSB IXLF1VRW IXLX1EER IXLM1TB2 IXLM1MST IXLHA11 IXLHA31
SA380658 | SA380677 | SA380665 | SA231378 |
Fix information
Fixed component name
CROSS SYS.EXT.S
Fixed component ID
5752SCIXL
Applicable component levels
R7B0 PSY UA94775
UP17/12/27 P F712
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7B0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7B0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: