A fix is available
APAR status
Closed as program error.
Error description
Customer was attempting to test a failure of connectivity to the secondary PPRC volumes. The expected behavior was HSIB should recognize the loss from one system and maintain hyperswap enablement with message: IOSHM0803E HyperSwap enabled with limited capability . - The expected wto was issued, however the display commands did not reflect any indication of limited enablement. - D HS,CONFIG command did show Indicate 1 SYSTEMS IMPACTED. - The customer is looking for a better set of display commands to properly reflect this condition where HSIB is LIMITED by one or more systems and which system(s) are limited? - The message: IOSHM0806I Unable to verify PPRC secondary device connectivity was periodically displayed on the system which lost the connectivity.
Local fix
Look for message IOSHM0806I on one or more systems to find which system lost connectivity. D HS,CONFIG(DETAIL) will show the detail on each of the individual systems as to where the connectivity is lost.
Problem summary
**************************************************************** * USERS AFFECTED: Users at HBB7780 and above that use Basic * * HyperSwap function. * **************************************************************** * PROBLEM DESCRIPTION: HyperSwap status in DISPLAY message * * MSGIOSHM0303I does not always indicate * * the correct enablement status and may * * not be consistent with MSGIOSHM0803E * * and MSGIOSHM0805I messages * **************************************************************** * RECOMMENDATION: * **************************************************************** HyperSwap status in DISPLAY HS,STATUS command response (MSGIOSHM0303I) does not always indicate the correct enablement status and may not be consistent with IOSHM0803E and IOSHM0805I messages. -MSGIOSHM0303I indicates HyperSwap is enabled when the loss of connectivity to the secondary devices in the configurations causes HyperSwap to have limited enablement -In a multi-target HyperSwap configuration when connectivity is lost to secondary devices in a configuration, however, there remains one configuration with connectivity from all systems, MSGIOSHM0303I indicates HyperSwap is enabled but message MSGIOSHM0803E is issued indicating limited availability. -The disablement reasons in the MSGIOSHM0303I response to the DISPLAY HS,STATUS command are not always shown correctly when a system has lost connectivity to the secondary devices or when one or more HyperSwap configurations are loaded, however no configuration is capable of HyperSwap.
Problem conclusion
Correct the reporting of the HyperSwap enablement status as follows: -Ensure that the HyperSwap status indicated by MSGIOSHM0303I indicates limited enablement when one or more systems has lost connectivity to the secondary devices of the configuration to be used for HyperSwap. -In a multi-target HyperSwap configuration when connectivity is lost to secondary devices in a configuration, however, there remains one configuration with connectivity from all systems and capable of HyperSwap, ensure that MSGIOSHM0803E is not issued. -Update MSGIOSHM0303I response to the DISPLAY HS,STATUS to provide the appropriate disablement reason when a system has lost connectivity to the secondary devices or when one or more HyperSwap configurations are loaded, however no configuration is capable of HyperSwap. KEYWORDS: HYPERSWP/K
Temporary fix
Comments
APAR Information
APAR number
OA50053
Reported component name
IOS
Reported component ID
5752SC1C3
Reported release
790
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-03-02
Closed date
2016-06-03
Last modified date
2016-07-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA81886 UA81887 UA81888
Modules/Macros
IOSHMDSP IOSHMEDS
Fix information
Fixed component name
IOS
Fixed component ID
5752SC1C3
Applicable component levels
R7A0 PSY UA81886
UP16/06/15 P F606
R780 PSY UA81887
UP16/06/15 P F606
R790 PSY UA81888
UP16/06/15 P F606
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"790","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"790","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
04 July 2016