Error description

  • New Function - Require the XRC CONTROL data set to be a minimum
    of one cylinder in size and be on a cylinder boundary.
    
    The procedure to update an existing XRC CONTROL data set:
    
    1. Issue the XSUSPEND command with the TIMEOUT option to suspend
    the session if it is still active.
    2. If the session is coupled, issue the XCOUPLE command with the
    PURGE option to uncouple it.
    3. Make a backup copy of the old control data set.
    4. Delete the old control data set and allocate the new control
    data set with new space requirements.
    5. Restart the XRC session using the XSTART command with
    SESSIONTYPE(XRC).
    6. Perform resynchronization using the normal procedures for
    your installation.).
    7. F ANTAS000,LISTSESS ALL to verify the storage control
    sessions are available.
    
    WARNING: DO NOT SKIP THE XCOUPLE PURGE IN STEP 2.  IF IT IS
    SKIPPED THEN THE XSTART PROCESSING WILL XEND THE STORAGE
    CONTROL SESSION BECAUSE THE CONTROL DATASET IS EMPTY.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Extended Remote Copy (XRC).         *
    ****************************************************************
    * PROBLEM DESCRIPTION: APAR OA49548 will require the           *
    *                      XRC CONTROL data set to be a minimum    *
    *                      of one cylinder in size and be on a     *
    *                      cylinder boundary.  Once this APAR      *
    *                      OA49548 is applied to a system, an      *
    *                      XSTART command will fail (initial       *
    *                      start OR re-start) if either of these   *
    *                      two conditions fail to be met.          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

Temporary fix

Comments

  • A message will be produced that notifies the user if either
    of the following conditions fail to be met:
    1)  XRC CONTROL data set is not at least one cylinder in size.
    2)  XRC CONTROL data set is not on a cylinder boundary.
    
    The following updates will be reflected in a future revision
    of z/OS MVS System Messages, Volume 1(ABA-AOM)(SA38-0668):
    
    1.1.1 ANTB8006W
    ANTB8006W XRC SESSION(session_id) CONTROL DATA SET NOT ONE CYL
    OR NOT ON A CYL BOUNDARY
    
    Explanation: The control data set for session session_id
    is not one cylinder or does not start on a cylinder boundary.
    
    Source: Extended Remote Copy (XRC).
    
    System Action: XRC functions are active.
    
    System Programmer Response: Suspend XRC session, purge any
    coupled/clustered sessions, delete, reallocate the control
    dataset to be one cylinder in size, and restart the session
    or reference Advanced Copy Services on how to re-allocate
    existing control data sets.
    
    
    The following updates will be reflected in a future revision
    of the z/OS DFSMS Advanced Copy Services manual (SC23-6847):
    
    Chapter 4. Setting up the extended remote copy environment
    Section: Specifying XRC journal, control, and state date sets
    Sub-section: Specifying the control data set
    
    Add the following bullet:
    - Allocate one cylinder of space
    
    Modify the JCL with the following change:
    - SPACE=(CYL,(1,0))
    KEYWORDS: D/T2105 D/T2107 XRC/K
    

APAR Information

  • APAR number

    OA49555

  • Reported component name

    SYSTEM DATA MOV

  • Reported component ID

    5695DF117

  • Reported release

    210

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-12-09

  • Closed date

    2016-01-26

  • Last modified date

    2017-07-31

  • APAR is sysrouted FROM one or more of the following:

    OA49548

  • APAR is sysrouted TO one or more of the following:

    UA80462 UA80463

Modules/Macros

  • ANTS4013 ANTXJRIN ANTXJTIN ANTXSMID
    

Publications Referenced
SA380668XXSC236847XX   

Fix information

  • Fixed component name

    SYSTEM DATA MOV

  • Fixed component ID

    5695DF117

Applicable component levels

  • R210 PSY UA80462

       UP16/02/09 P F602 Ž

  • R220 PSY UA80463

       UP16/02/09 P F602 Ž

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
31 July 2017