A fix is available
APAR status
Closed as program error.
Error description
With ptf UA90977, UA90978 or UA90979 applied, it is possible for IRASTMON to overlay location x'208' field PSAPCCAV which is the pointer to the PCCA. The problem only occurs with the fix for OA46396 applied.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of z/OS 1.13 (HBB7780) and * * above. * **************************************************************** * PROBLEM DESCRIPTION: With ptf UA90977, UA90978 or UA90979 * * applied, it is possible for IRASTMON to * * overlay location x'208' field PSAPCCAV * * which is the pointer to the PCCA. The * * problem only occurs with the fix for * * OA46396 applied. * **************************************************************** * RECOMMENDATION: * **************************************************************** The procedure DeactivateMonitoring resets the monitoring counts in the STMA and also resets Rax_FreemainedFramesTarget when monitoring stops. In the case of the problem, an address space was going through termination and RSM had freemained the RAX and zeroed the ASCBRSME field. SRM module IRASTMON used an invalid RAX pointer of zero and stored x'100' at location x'208' instead of into a RAX.
Problem conclusion
The procedure DeactivateMonitoring in IRASTMON has been updated to check the OUCBNSWI flag, which shows when the address space is in termination, and a reset of monitoring counts in the STMA and Rax_FreemainedFramesTarget will only be done for active address spaces.
Temporary fix
Comments
APAR Information
APAR number
OA48858
Reported component name
SRM - SYS RSRCE
Reported component ID
5752SC1CX
Reported release
780
Status
CLOSED PER
PE
YesPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-09-04
Closed date
2015-09-10
Last modified date
2015-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA78964 UA78965 UA78974
Modules/Macros
IRASTMON
Fix information
Fixed component name
SRM - SYS RSRCE
Fixed component ID
5752SC1CX
Applicable component levels
R7A0 PSY UA78964
UP15/09/30 P F509 «
R780 PSY UA78974
UP15/09/30 P F509 «
R790 PSY UA78965
UP15/09/30 P F509 «
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"780","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"780","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: