A fix is available
APAR status
Closed as program error.
Error description
After applying PTFs UA90740 (HBB7780) or UA90741 (HBB7790) for APAR OA44240, duplicate volumes may come online when IPLing from the alternate subchannel set. For example, devices B000/1B000 are a PPRC pair. Device A000 has the same VOLSER as B000/1B000. When IPLing SS1, both devices A000 and 1B000 come online with the same volser. Device B000 remains offline as expected. Known Environment: Systems running with alternate Subchannel Sets at IPL with the PTFs for APAR OA44240 installed and active. . Known Impact: Potential data integrity issue due to undetected ONLINE duplicate VOLIDs when IPLing with an alternate subchannel set with a configuration error (and no error message). . PE Information: User's Affected: Users at HBB7780 and above with the PTFs for APAR OA44240 (UA90740 at HBB7780 or UA90741 at HBB7790) installed and active. . User Impact: OA44240 PTFs: HBB7780 PSY UA90740 HBB7790 PSY UA90741 . APAR OA44240 provides a large amount of new function and capability but introduces this problem when using multiple subchannel sets and mismatched configurations. . Recommendation: Keep the PTFs on to enable all the new functions but use extra care when IPLing a recently updated configuration and IPLing the system with an alternate subchannel set.
Local fix
Manually vary offline one of the duplicate volumes. Subsequent VARY will not allow for the duplicate volumes to be brought online simultaneously
Problem summary
**************************************************************** * USERS AFFECTED: Users at HBB7780 and above with the PTFs for * * OA44240 (UA90740 and UA90741) installed * * and running with an alternate subchannel set * **************************************************************** * PROBLEM DESCRIPTION: During IPL with an alternate * * subchannel set, IPL phase duplicate * * VOL ID check processing is NOT * * detecting duplicate volume IDs thus * * allowing multiple volumes with the * * same ID to be online at the same time. * **************************************************************** * RECOMMENDATION: * **************************************************************** During IPL with an alternate subchannel set duplicate VOL ID Check processing is scanning the list of online devices for the CURRENT subchannel set instead of the ACTIVE one.
Problem conclusion
Change the DUP VOL ID check processing in IEAVNP02 to use the ACTIVE subchannel set when scanning onine devices for duplicates
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
OA48844
Reported component name
IOS
Reported component ID
5752SC1C3
Reported release
790
Status
CLOSED PER
PE
YesPE
HIPER
YesHIPER
Special Attention
NoSpecatt
Submitted date
2015-09-04
Closed date
2015-11-13
Last modified date
2016-01-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA79791 UA79792 UA79793
Modules/Macros
IEAVNP02
Fix information
Fixed component name
IOS
Fixed component ID
5752SC1C3
Applicable component levels
R7A0 PSY UA79791
UP15/12/23 P F512 ®
R780 PSY UA79792
UP15/12/23 P F512 ®
R790 PSY UA79793
UP15/12/23 P F512 ®
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"790","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"790","Edition":"","Line of Business":{"code":"","label":""}}]