IBM Support

OA48001: WAIT040 DUE TO ABENDC0D UNDER NIP RIM IEAVNPD7

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IAXMH issues AbendC0D RSNF3333333 because it is unable to obtain
    a quad frame during NIP.  This results in WAIT STATE 040.  This
    is occurring because the quad frame area has not been built.
    OA44207 removed code in IAXMT that is preventing the quad frame
    area to be built, if REAL= IEASYSxx parameter is set to REAL=0.
    
    This occurs on systems with a small assignment of online real
    storage, 1024MB or less with increment size of 512MB, 512MB or
    less with increment size of 256MB, 256MB or less with increment
    size of 128MB.
    
    
    PE Information:
    User's Affected: Users with OA44207 installed, and IPLing
    with less than 2G of storage.
    UA74198(HBB7790)
    
    User Impact:
    Systems defined with less than 2G of storage and IEASYSxx
    parmlib REAL=0 coded may fail to ipl.  For machines with 256M
    increment size, the failure will occur with less than 768M
    online.  For machines with 512M increments, the failure is seen
    with less than 1.5G online.  APAR OA44207 fixed the problem it
    reported but introduced a new problem described above.  If
    OA44207 is already installed and 2G or more of storage will
    always be available, there is no need to remove the PTFs.
    

Local fix

  • Add more real storage such that the following exists:
    If your storage increment size is 128MB, 256MB, or 512MB, ensure
    at least 3 storage increments are online at IPL.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of HBB7790 and above with small    *
    *                 real memory configurations and specifying    *
    *                 REAL=0 in IEASYSxx.                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: WAIT040 due to ABENDC0D under NIP RIM   *
    *                      IEAVNPD7 when 2 or less increments      *
    *                      of real storage are online at IPL       *
    *                      and REAL=0 in IEASYSxx. Examples of     *
    *                      failing configurations:                 *
    *                      1024MB or less with increment size of   *
    *                      512MB, 512MB or less with increment     *
    *                      size of 256MB, 256MB or less with       *
    *                      increment size of 128MB.                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Module IAXMT selects the real storage location for the quad
    frame area.  The system was IPLed with only one storage
    increment, which was marked as preferred storage.  The search
    routine was only looking for non-preferred storage and failed
    to create a quad frame area.  The subsequent quad frame
    request by IAXMH could not be satisfied resulting in the
    ABENDC0D and WAIT040.
    

Problem conclusion

  • Code in the quad area selection routine is changed to select a
    preferred area if no non-preferred area is available.
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    OA48001

  • Reported component name

    RSM - REAL STOR

  • Reported component ID

    5752SC1CR

  • Reported release

    790

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-06-03

  • Closed date

    2015-07-16

  • Last modified date

    2015-08-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA78171 UA78172

Modules/Macros

  • IAXMT
    

Fix information

  • Fixed component name

    RSM - REAL STOR

  • Fixed component ID

    5752SC1CR

Applicable component levels

  • R7A0 PSY UA78171

       UP15/07/29 P F507 ®

  • R790 PSY UA78172

       UP15/07/29 P F507 ®

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"790","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"790","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: