IBM Support

OA39414: EZZ4321I ERROR: CODE=0810004A DURING SETUP PHASE ON CONNECTION FOR DEVICE IUTSAMEH

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Some time after VTAM start, when the EE XCA Major Node is
    activated, the following message is seen in TCP/IP: EZZ4321I
    ERROR: CODE=0810004A DURING SETUP PHASE ON CONNECTION TO
    x.x.x.x FOR DEVICE IUTSAMEH. All EE XCA lines remain in PALNK
    status.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All using Enterprise Extender (EE).          *
    ****************************************************************
    * PROBLEM DESCRIPTION: Attempt to activate the EE XCA Major    *
    *                      Node yields the following TCP/IP        *
    *                      message:                                *
    *                                                              *
    *                          EZZ4321I ERROR: CODE=0810004A       *
    *                          DURING SETUP PHASE ON CONNECTION    *
    *                          TO  x.x.x.x FOR DEVICE IUTSAMEH.    *
    *                                                              *
    *                      All EE XCA lines remain in PALNK        *
    *                      status.                                 *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    With VTAM active, HPR is running and allocating TIPACs for
    packing buffers.  These TIPACs may be in the T100 or T200
    format.  As they are discarded via TSDSCARD/TSALERT, ISTTSCUD
    checks each buffer to determine if it might be an EE activation
    request.  ISTTSCUD looks in the PDUWA to do so.
    
    Because these TIPACs are not in the expected TI00 format, the
    field XBFL_PDUWA is actually pointing to an ISTSND block.
    ISTTSCUD references the ISTSND as though it were a PDUWA and
    falsely decrements the TSEXT EE count as a result, making the
    count go negative.
    
    Some time later, request to activate the EE XCA Major Node is
    issued.  Because the TSEXT EE count is not zero, the request
    fails. VTAM must be recycled to get EE to activate again.
    

Problem conclusion

  • The PDUWA_EE_Setup indicator has been moved the base TSCB,
    replacing an unused bit (TSCFIS).  This will remove the
    dependency ISTTSCUD currently has on the TIPAC being in the
    proper format when checking for EE activation requests.
    
    All parts that reference PDUWA_EE_Setup have been changed to
    reference the new bit TSC_EE_Setup instead.
    
      ISTTSCUD
      IUTLLCIX
      IUTLLCCS
      IUTLLCGI
    
    As a precaution, ISTTSCUD will reset the bit after checking it.
    This will ensure the bit is not left on residually should the
    the buffer be reused without being cleared.
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    OA39414

  • Reported component name

    VTAM V4 MVS/ESA

  • Reported component ID

    569511701

  • Reported release

    1A0

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-04-25

  • Closed date

    2012-05-25

  • Last modified date

    2012-05-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA65459

Modules/Macros

  • ISTAUCLA ISTTSCB  ISTTSCUD IUTLLCCS IUTLLCGI
    IUTLLCIX IUTPDUWA
    

Fix information

  • Fixed component name

    VTAM V4 MVS/ESA

  • Fixed component ID

    569511701

Applicable component levels

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1A0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCY4DZ","label":"DO NOT USE"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1A0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
25 May 2012