OA36310: PREDICTIVE FAILURE ANALYSIS ABEND006 NOT DOCUMENTED Z/OS 1.10 & Z/OS 1.11 PFA

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as documentation error.

Error description

  • Abend006 for Predictive Failure Analysis (PFA compid 5752SCPFA)
    is not documented in MVS System Codes for z/OS 1.10 (R750) and
    z/OS 1.11 (R760).
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of HBB7750 who have installed      *
    *                 OA27165 PFA SPE.                             *
    *                 All users of HBB7760 exploiting the          *
    *                 Predictive Failure Analysis (PFA).           *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    PFA ended with abend S0006 RSN031B000A.  The abend code
    is not documented in MVS System Codes book.
    

Problem conclusion

  • Documentation HOLD for OA36130.
    
    The following updates have been made to the specified manuals:
    
    1.z/OS V1R10.0 MVS System Codes (SA22-7626-19)
    2.z/OS V1R11.0 MVS System Codes (SA22-7626-21)
    
    Following will be added to the System Completion Codes
    
     006
    
    
    Explanation: Predictive Failure Analysis (PFA) detected an
    unrecoverable error that caused it to terminate abnormally.
    
    The reason code identifies the source of the error.  The
    reason code has the format of X'mmmmrrrr', where mmmm
    represents the failing entry point's module ID, and rrrr
    represents the reason code.
    
    rrrr Code Explanation
    
    0001
    Unable to find requested entry point
    
    0002
    Unable to load requested entry point
    
    0003
    Exhausted stack space.
    
    0004
    Unknown server request.
    
    0005
    Job step task posted in error.
    
    0006
    Unable to set an ESTAE.
    
    0007
    Server task ended.
    
    0008
    Server task ETXR error.
    
    0009
    ProcARequest error
    
    000A
    Unable to create name/token pair.
    
    000B
    Unable to attach task.
    
    000C
    Unable to establish ENF listener.
    
    000D
    Unable to create latches.
    
    System Action: The system issues an ABEND dump and abnormally
    ends the PFA address space.
    
    Operator Response: Contact your system programmer.
    
    System Programmer Response:  Search the problem reporting
    databases for a fix for the problem.  If no fix exists,
    collect the ABEND dump, then contact the IBM Support Center.
    
    
    NOTE:  The ABEND code S0006 is replaced by ABEND code S050E
           and is Documented in HBB7770 and above.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA36310

  • Reported component name

    Z/OS PFA

  • Reported component ID

    5752SCPFA

  • Reported release

    750

  • Status

    CLOSED DOC

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-04-28

  • Closed date

    2011-05-04

  • Last modified date

    2012-05-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Publications Referenced
SA22762619 SA22762621      

Fix information

Applicable component levels



Rate this page:

(0 users)Average rating

Document information


More support for:

z/OS family

Software version:

750

Operating system(s):

MVS, z/OS

Reference #:

OA36310

Modified date:

2012-05-10

Translate my page

Machine Translation

Content navigation