A fix is available
APAR status
Closed as program error.
Error description
While processing a job step that has duplicate DDNAMES coded and at least one of the DDNAMES points to a JES data set (SYSIN, SYSOUT, etc.) an extend failure can occur. This error occurs when the non-JES data set is attempting to extend to a second volume and this candidate volume was not resolved to a specific volser prior to the step beginning. The error recieved is: IEC032I E37-08,IFG0554P Dataset will not extend Additional Keywords: MSGIEC032I ABENDE37 RC08 RC8 MSGIDC3009I RC132 RSN10 Module IGG0CLXC XC
Local fix
- Remove or rename one of the DDNAMEs - Use guaranteed space to ensure a real volser is assigned to the candidate volumes
Problem summary
**************************************************************** * USERS AFFECTED: All with HDZ11F0 and above. * **************************************************************** * PROBLEM DESCRIPTION: MSGIEC614I RC0 RSN040342D3 and * * MSGIEC032I ABENDE37 RC8 may occur for a * * VSAM data set extending if the job * * doing the extend has a duplicate DD * * name for the DD statement describing * * the VSAM data set. * **************************************************************** * RECOMMENDATION: * **************************************************************** The logic that verifies and captures UCB addresses incorrectly processed the duplicate DD name, even though it was physically after the original DD name. If that duplicate name references a JES data set (e.g. SYSIN or SYSOUT), there is no UCB associated with it, hence the failure.
Problem conclusion
The logic has been changed to only verify the first DD it finds with the matching name, according to documented rules for processing DD statements. However, it is strongly recommended customers remove duplicate DD statements.
Temporary fix
Please apply ++APAR and provide feedback.
Comments
APAR Information
APAR number
OA05493
Reported component name
DFSMS/MVS SMS
Reported component ID
5695DF101
Reported release
1G0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2003-11-05
Closed date
2003-11-25
Last modified date
2004-01-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA07280 UA07281 UA07282
Modules/Macros
IGGCCX IGG0CLXC
Fix information
Fixed component name
DFSMS/MVS ICF C
Fixed component ID
5695DF105
Applicable component levels
R1F0 PSY UA07280
UP03/12/11 P F312
R1G0 PSY UA07281
UP03/12/11 P F312
R1H0 PSY UA07282
UP03/12/11 P F312
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.