A fix is available
APAR status
Closed as program error.
Error description
topas -C shows stale data for the partition where xmtopas is killed and restarted
Local fix
Problem summary
topas -C shows stale data for the partition where xmtopas is killed and restarted
Problem conclusion
Fixed the code such that the data of the partition where xmtopas is restarted is refreshed.
Temporary fix
Comments
5300-11 - use AIX APAR IZ90756 5300-12 - use AIX APAR IZ90807 6100-04 - use AIX APAR IZ87720 6100-05 - use AIX APAR IZ84911 6100-06 - use AIX APAR IZ85496 7100-00 - use AIX APAR IZ85663
APAR Information
APAR number
IZ90807
Reported component name
AIX 5.3
Reported component ID
5765G0300
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2010-12-13
Closed date
2010-12-13
Last modified date
2013-04-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX 5.3
Fixed component ID
5765G0300
Applicable component levels
R530 PSY U838599
UP11/02/22 I 1000
PTF to Fileset Mapping
U838599 perfagent.tools 5.3.12.3
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11P","label":"APARs - AIX 5.3 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"530","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
17 April 2013