A fix is available
APAR status
Closed as program error.
Error description
The new "retry" option of the logger command (-r) while shown correctly as a simple option in the usage message,currently requires an option-argument; the command is indifferent to the actual value of the argument. This option (-r) retries sending a message when, and as long as, transient errors are encountered (instead of failing upon the first such error). The option is useful mainly when large batches of messages are to be logged.
Local fix
Follow -r with a value argument, e.g: -r 1
Problem summary
Retry option of logger command requires unneeded option-argument.
Problem conclusion
Remove extraneous ':' for command's -r option.
Temporary fix
Comments
5300-09 - use AIX APAR IZ82314 5300-10 - use AIX APAR IZ82680 5300-11 - use AIX APAR IZ77567 5300-12 - use AIX APAR IZ81839 6100-02 - use AIX APAR IZ79593 6100-03 - use AIX APAR IZ79632 6100-04 - use AIX APAR IZ79092 6100-05 - use AIX APAR IZ78865 6100-06 - use AIX APAR IZ78290 6100-06 - use AIX APAR IZ78255 7100-00 - use AIX APAR IZ82054
APAR Information
APAR number
IZ77567
Reported component name
AIX 5.3
Reported component ID
5765G0300
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2010-06-16
Closed date
2010-06-28
Last modified date
2013-03-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
IZ78255 IZ78290 IZ78865 IZ79092 IZ79593 IZ79632 IZ81839 IZ82054
IZ82314 IZ82680
Fix information
Fixed component name
AIX 5.3
Fixed component ID
5765G0300
Applicable component levels
R530 PSY U837635
UP10/09/20 I 1000
PTF to Fileset Mapping
U837635 bos.rte.serv_aid 5.3.11.3
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11P","label":"APARs - AIX 5.3 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"530","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
28 March 2013