Direct links to fixes
APAR status
Closed as program error.
Error description
After a migration completed, a subsequent clare fails with error: "ERROR: network_fdt must be at least 5000 ms or 0 (unset) ERROR: Failed to change tunable network_fdt. 0 tunables updated on <<cluster_name>> ERROR: Updating the cluster in AIX failed. Check output for errors in local cluster configuration, correct them, and try synchronization again."
Local fix
Manually reset network_fdt tunable Date:08/03/2017 After successful migration from 7.1.3.6 to 7.2.1.0 for all the nodes, run the below command first and then perform the cluster varification. /usr/es/sbin/cluster/utilities/clmgr modify cluster NETWORK_FAILURE_DETECTION_TIME=20
Problem summary
After a successful migration from 7.1.3.6 to 7.2.1.0, invalid network_fdt value is being updated and due to this a subsequent cldare getting failed.
Problem conclusion
Modified code to show proper network_fdt value.
Temporary fix
Comments
APAR Information
APAR number
IV96095
Reported component name
POWERHA SYSMIR
Reported component ID
5765H3900
Reported release
720
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2017-05-10
Closed date
2017-05-10
Last modified date
2017-05-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
POWERHA SYSMIR
Fixed component ID
5765H3900
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSXU4N","label":"PowerHA SystemMirror Enterprise Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
19 October 2021