IBM Support

IV93164: ASSERT IN ENTCORE_RESTART_HANDLER IN SHIENTDD DRIVER APPLIES TO AIX 7100-03 17/04/28 PTF PECHANGE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The system with adapter FC EN0S crashes with the
    following
    stack trace:
    (0)> f
    pvthread+000200 STACK:
    [0482BAF0]entcore_restart_handler+0002F0
    (0000000000000003 [??])
    [0026330C]i_offlevel+00014C (??, ??)
    [00262D8C]i_softmod+0005EC ()
    [002019AC]flih_util+000258 ()
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:
    * Systems running the 7100-03 Technology Level with
    * any of the following filesets at or between the given levels:
    * MIN          MAX          FILESET
    * 7.1.3.45     7.1.3.47     devices.ethernet.shi.rte
    ****************************************************************
    * PROBLEM DESCRIPTION:
    * The system with adapter FC EN0S crashes with the
    * following
    * stack trace:
    * (0)> f
    * pvthread+000200 STACK:
    *  0482BAF0 entcore_restart_handler+0002F0
    * (0000000000000003  ?? )
    *  0026330C i_offlevel+00014C (??, ??)
    *  00262D8C i_softmod+0005EC ()
    *  002019AC flih_util+000258 ()
    ****************************************************************
    * RECOMMENDATION:
    * Install APAR IV93164.
    ****************************************************************
    

Problem conclusion

  • Driver is fixed to handle adapter restart state.
    

Temporary fix

Comments

  • 7100-03 - use AIX APAR IV93164
    

APAR Information

  • APAR number

    IV93164

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-02-07

  • Closed date

    2017-02-07

  • Last modified date

    2017-04-28

  • APAR is sysrouted FROM one or more of the following:

    IV79989

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U874147

       UP17/04/10 I 1000