Direct link to fix
APAR status
Closed as program error.
Error description
The PowerHA cluster verification fails with an ERROR in case the major number of a shared VG is not the same on all nodes even if no NFS export is configured. root@ha1clJ:/ # ls -l /dev/clJvg1 crw-rw---- 1 root system 43, 0 Sep 3 2015 /dev/clJvg1 root@ha2clJ:/ # ls -l /dev/clJvg1 crw-rw---- 1 root system 45, 0 Sep 3 2015 /dev/clJvg1 -> Major number for VG clJvg1 is not the same on both nodes. root@ha1clJb1:/ # clshowres -g clJrg1 Resource Group Name clJrg1 Participating Node Name(s) ha1clJb1 ha2clJb1 ... Filesystems/Directories to be exported (NFSv3) Filesystems/Directories to be exported (NFSv4) ... Volume Groups clJvg1 ... -> No NGS export is defined root@ha1clJb1:/ # /usr/es/sbin/cluster/diag/clver -r ... ERROR: The major number for VG clJvg1 is not the same on all nodes. ... Verification exiting with error count: 1 The VG major number is only relevant if a filesystem or directory is exported via NFS. So in case no NFS export is defined a WARNING is sufficient.
Local fix
Problem summary
The PowerHA cluster verification fails with an ERROR in case the major number of a shared VG is not the same on all nodes even if no NFS export is configured
Problem conclusion
Modified code to display warning instead of error message where major number of shared VG is not same across all the nodes when NFS export is not configured.
Temporary fix
Comments
APAR Information
APAR number
IV86812
Reported component name
POWERHA SYSMIR
Reported component ID
5765H3900
Reported release
713
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2016-07-12
Closed date
2016-07-12
Last modified date
2016-07-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
POWERHA SYSMIR
Fixed component ID
5765H3900
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSXU4N","label":"PowerHA SystemMirror Enterprise Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"","label":""}}]