  • Closed as program error.

Error description

  • The PowerHA cluster verification fails with an ERROR
    in case the major number of a shared VG is not the
    same on all nodes even if no NFS export is configured.
    
    root@ha1clJ:/ # ls -l /dev/clJvg1
    crw-rw---- 1 root system 43, 0 Sep 3 2015 /dev/clJvg1
    
    root@ha2clJ:/ # ls -l /dev/clJvg1
    crw-rw---- 1 root system 45, 0 Sep 3 2015 /dev/clJvg1
    
    -> Major number for VG clJvg1 is not the same on
       both nodes.
    
    root@ha1clJb1:/ # clshowres -g clJrg1
    
    Resource Group Name           clJrg1
    Participating Node Name(s)    ha1clJb1 ha2clJb1
    ...
    Filesystems/Directories to be
     exported (NFSv3)
    Filesystems/Directories to be
     exported (NFSv4)
    ...
    Volume Groups                 clJvg1
    ...
    
    -> No NGS export is defined
    
    root@ha1clJb1:/ # /usr/es/sbin/cluster/diag/clver -r
    ...
    ERROR: The major number for VG clJvg1 is not the
     same on all nodes.
    ...
    Verification exiting with error count: 1
    
    The VG major number is only relevant if a filesystem or
    directory is exported via NFS. So in case no NFS export
    is defined a WARNING is sufficient.
    

Local fix

Problem summary

  • The PowerHA cluster verification fails with an ERROR
    in case the major number of a shared VG is not the
    same on all nodes even if no NFS export is configured
    

Problem conclusion

  • Modified code to display warning instead of error message
    where major number of shared VG is not same across all the
    nodes when NFS export is not configured.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV86812

  • Reported component name

    POWERHA SYSMIR

  • Reported component ID

    5765H3900

  • Reported release

    713

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2016-07-12

  • Closed date

    2016-07-12

  • Last modified date

    2016-07-12

  • APAR is sysrouted FROM one or more of the following:

    IV85977

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    POWERHA SYSMIR

  • Fixed component ID

    5765H3900

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSXU4N","label":"PowerHA SystemMirror Enterprise Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: