Error description
A perfectly working PowerHA cluster (712 or 713) has AIX upgraded to 7.1 TL4 or 7.2. Now every attempt to Verify and Synchronize gets these error messages -- ERROR: New node_timeout value 20000 ms is not at least 10000 ms greater than network_fdt 20000 ms ERROR: Failed to change tunable node_timeout. ... cldare: Error detected during synchronization. and the Verify and Synchronize operation fails.
Local fix
Change the Node Failure Detection Timeout to 30 or more.
Problem summary
A perfectly working PowerHA cluster (712 or 713) has AIX upgraded to 7.1 TL4 or 7.2. Now every attempt to Verify and Synchronize gets these error messages -- ERROR: New node_timeout value 20000 ms is not at least 10000 ms greater than network_fdt 20000 ms ERROR: Failed to change tunable node_timeout. ... cldare: Error detected during synchronization. and the Verify and Synchronize operation fails.
Problem conclusion
Modified the code to pass allowed node_timeout values to CAA to avoid verify & sync failures.
Temporary fix
Comments
APAR Information
APAR number
IV83760
Reported component name
POWERHA SYSMIR
Reported component ID
5765H3900
Reported release
713
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2016-04-15
Closed date
2016-06-13
Last modified date
2016-06-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
POWERHA SYSMIR
Fixed component ID
5765H3900
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSXU4N","label":"PowerHA SystemMirror Enterprise Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
19 October 2021