IBM Support

IV70296: "COULD NOT REGISTER" MSG LOGGED WHEN IPV6 ON LOOPBACK IS REMOVED APPLIES TO AIX 7100-02

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • rpc.statd logs error message like one below when IPv6 on
    loopback device is removed. The error itself does not
    indicate critical conditions but rather a debug
    information customer should not be worried about.
    
    This APAR changes the log priority of the line to debug
    level so that it won't show up any longer unless debug
    message level is chosen for troubleshooting with support
    team.
    
    error statd: Could not register prog 100024 vers 1 on
    udp6
    error statd: Could not register prog 100024 vers 1 on
    tcp6
    

Local fix

Problem summary

  • Messages similar to the following:
    Nov  7 10:25:17 reg34 daemon:err|error statd 2621650 :
      svc_tp_create: Could not register prog 100024 vers 1 on udp6
    Nov  7 10:25:17 reg34 daemon:err|error statd 2621650 :
      svc_tp_create: Could not register prog 100024 vers 1 on tcp6
    Nov  7 10:25:17 reg34 daemon:err|error statd 2621650 :
      svc_tp_create: Could not register prog 100024 vers 1 on udp6
    

Problem conclusion

  • change level of logged message from Error to Debug
    

Temporary fix

Comments

  • 6100-08 - use AIX APAR IV70052
    6100-09 - use AIX APAR IV66760
    6100-09 - use AIX APAR IV66760
    7100-02 - use AIX APAR IV70296
    7100-03 - use AIX APAR IV66966
    

APAR Information

  • APAR number

    IV70296

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2015-02-28

  • Closed date

    2015-02-28

  • Last modified date

    2015-09-30

  • APAR is sysrouted FROM one or more of the following:

    IV66760

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U864299

       UP15/09/21 I 1000

PTF to Fileset Mapping

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSMV87","label":"AIX 6.1 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMVAX","label":"AIX Express Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11R","label":"AIX 7.1 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"","label":""}}]