IBM Support

IV69527: HEAVY TRANSMIT DATA ON FC5899/FC1763 RESULTS IN MACHINE HANG APPLIES TO AIX 6100-09 15/06/01 PTF PECHANGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When heavy load of transmit data is present on machine, there
    is a chance of machine hang.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:
    * Systems running the 6100-09 Technology Level with
    * devices.pciex.e4145616e4140518.rte at or between 6.1.9.0 and
    * 6.1.9.30
    ****************************************************************
    * PROBLEM DESCRIPTION:
    * When heavy load of transmit data is present on machine, there
    * is a chance of machine hang.
    ****************************************************************
    * RECOMMENDATION:
    * Install APAR IV69527.
    ****************************************************************
    

Problem conclusion

  • Counter that is causing the issue was cleared at appropriate
    place in the driver.
    

Temporary fix

Comments

  • 6100-09 - use AIX APAR IV69527
    7100-03 - use AIX APAR IV69636
    

APAR Information

  • APAR number

    IV69527

  • Reported component name

    AIX 610 STD EDI

  • Reported component ID

    5765G6200

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Submitted date

    2015-02-16

  • Closed date

    2015-02-16

  • Last modified date

    2015-11-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IV69538 IV69636

Fix information

  • Fixed component name

    AIX 610 STD EDI

  • Fixed component ID

    5765G6200

Applicable component levels

  • R610 PSY U861519

       UP15/11/22 I 1000

PTF to Fileset Mapping

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11Q","label":"AIX 6.1 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSMV87","label":"AIX 6.1 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMVAX","label":"AIX Express Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSAUMY","label":"IBM AIX Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11Q","label":"AIX 6.1 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11R","label":"APARs - AIX 7.1 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]

Document Information

Modified date:
17 December 2021