IBM Support

IV64937: GENSYMS FAILED TO GENERATE SYMBOLS FOR THE BIGGER EXECUTABLE.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • gensyms failed to generate symbols for the bigger
    executable.
    If the executable size is around greater than 3GB then
    gensyms fails. It will work fine for smaller
    executable's.
    
    -> ls -l ibig.tsk_bk
    -rwxrwxrwx    1 root     system   4414085550 Aug 22 01:35
    ibig.tsk_bk
    root@daylight3:/test_fs
    
    -> /usr/bin/gensyms -k /unix -s -b ./ibig.tsk > t
    Warning: could  not get symbols for ./ibig.tsk
    root@daylight3:/test_fs
    

Local fix

Problem summary

  • gensyms failed to generate symbols for the bigger executable.
    If the executable size is around greater than 3GB then gensyms
    fails. It will work fine for smaller executable's.
    
    -> ls -l ibig.tsk_bk -rwxrwxrwx    1 root system  4414085550
    Aug 22 01:35 ibig.tsk_bk root@daylight3:/test_fs
    
    -> /usr/bin/gensyms -k /unix -s -b ./ibig.tsk > t Warning:
    could  not get symbols for ./ibig.tsk root@daylight3:/test_fs
    

Problem conclusion

  • Modified the gensyms code to generate symbols.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV64937

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2014-09-16

  • Closed date

    2014-09-16

  • Last modified date

    2015-11-22

  • APAR is sysrouted FROM one or more of the following:

    IV64783

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U861540

       UP15/11/22 I 1000

PTF to Fileset Mapping

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSMV87","label":"AIX 6.1 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMVAX","label":"AIX Express Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11R","label":"AIX 7.1 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
22 November 2015