IV59882: PACKET TRANSMISSION IS DELAYED IN FC5768 FAMILY ADAPTERS. APPLIES TO AIX 6100-08
APAR status
Closed as program error.
Error description
-
When packet transmission and adapter status query such as netstat -v or entstat are running at the same time, the packet to be transmitted will be delayed until next transmission. It may cause initial connection error of the application which has a short timeout value for connect.
Local fix
-
1. Do not run netstat -v or entstat when connect is being called. 2. Send packets repeatedly from the adapter with shorter interval than application timeout. For example, while true; do ping -c 1 <target address> sleep 1 done
Problem summary
-
When packet transmission and adapter status query such as netstat -v or entstat are running at the same time, the packet to be transmitted will be delayed until next transmission.
Problem conclusion
-
Driver is fixed to start send timer.
Temporary fix
Comments
-
6100-08 - use AIX APAR IV59882 6100-09 - use AIX APAR IV61671 6100-09 - use AIX APAR IV61671 7100-02 - use AIX APAR IV64214 7100-03 - use AIX APAR IV62023 7100-04 - use AIX APAR IV62074
APAR Information
APAR number
IV59882
Reported component name
VIRTUAL I/O SER
Reported component ID
5765G3400
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2014-04-29
Closed date
2014-06-24
Last modified date
2016-05-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
VIRTUAL I/O SER
Fixed component ID
5765G3400
Applicable component levels
R220 PSY
UP
PTF to Fileset Mapping
U865769 devices.pci.14106902.rte 6.1.8.19
Document information
More support for:
PowerVM VIOS Standard Edition
Software version: 220
Operating system(s): AIX
Reference #: IV59882
Modified date: 11 May 2016