IV59200: DIAGNOSTICS READ DATA BLOCK DOES NOT DISPLAY THE CORRECT DATA. APPLIES TO AIX 6100-07

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • The Diagnostic Disk Read Data function displays zeros when the
    number of blocks is greater than 5 blocks on 4k disk drive.
    

Local fix

Problem summary

  • The Diagnostic Disk Read Data function displays zeros when the
    number of blocks is greater than 5 blocks on 4k disk drive.
    

Problem conclusion

  • Incread the size of the read buffer.
    

Temporary fix

Comments

  • 6100-07 - use AIX APAR IV59200
    6100-08 - use AIX APAR IV59198
    6100-09 - use AIX APAR IV59101
    6100-09 - use AIX APAR IV59101
    6100-09 - use AIX APAR IV59101
    7100-01 - use AIX APAR IV59201
    7100-02 - use AIX APAR IV59199
    7100-03 - use AIX APAR IV59154
    7100-04 - use AIX APAR IV59151
    

APAR Information

  • APAR number

    IV59200

  • Reported component name

    AIX 610 STD EDI

  • Reported component ID

    5765G6200

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2014-04-14

  • Closed date

    2014-04-14

  • Last modified date

    2016-05-10

  • APAR is sysrouted FROM one or more of the following:

    IV59101

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX 610 STD EDI

  • Fixed component ID

    5765G6200

Applicable component levels

  • R610 PSY U866959

       UP14/08/11 I 1000



Document information

More support for: AIX Standard Edition

Software version: 610

Operating system(s): AIX

Reference #: IV59200

Modified date: 10 May 2016