IBM Support

IV56078: LACP PORT RECEIVE_TIME INITIALIZED TO ZERO APPLIES TO AIX 7100-04

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • During initialization, out of sync error should be logged after
    30 sec
    

Local fix

Problem summary

  • During initialization, out of sync error should be logged after
    30 sec
    

Problem conclusion

  • Correct the code to log out of sync error after 90sec
    

Temporary fix

Comments

  • 6100-07 - use AIX APAR IV58328
    6100-08 - use AIX APAR IV58016
    6100-09 - use AIX APAR IV56011
    6100-09 - use AIX APAR IV56011
    6100-09 - use AIX APAR IV56011
    7100-01 - use AIX APAR IV57664
    7100-02 - use AIX APAR IV57126
    7100-03 - use AIX APAR IV56015
    7100-04 - use AIX APAR IV56078
    

APAR Information

  • APAR number

    IV56078

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2014-02-28

  • Closed date

    2014-02-28

  • Last modified date

    2016-05-10

  • APAR is sysrouted FROM one or more of the following:

    IV56011

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U859744

       UP15/11/23 I 1000

PTF to Fileset Mapping



Document information

More support for: AIX Enterprise Edition

Software version: 710

Operating system(s): AIX

Reference #: IV56078

Modified date: 10 May 2016