APAR status
Closed as program error.
Error description
EEH error is logged against an 4 port Gb ethernet pci express device after AIX Diagnostics is run one of it's sibling devices.
Local fix
Problem summary
EEH error is logged against an 4 port Gb ethernet pci express device after AIX Diagnostics is run one of it's sibling devices.
Problem conclusion
Restore miscellaneous control register to value prior to running test units, on test unit close.
Temporary fix
Comments
5300-12 - use AIX APAR IV54520 6100-07 - use AIX APAR IV58266 6100-08 - use AIX APAR IV57872 6100-09 - use AIX APAR IV54616 6100-09 - use AIX APAR IV54616 6100-09 - use AIX APAR IV54616 7100-01 - use AIX APAR IV58222 7100-02 - use AIX APAR IV58165 7100-04 - use AIX APAR IV54620 7100-03 - use AIX APAR IV54629 7100-04 - use AIX APAR IV54620
APAR Information
APAR number
IV54520
Reported component name
AIX 5.3 EXT SUP
Reported component ID
5765G0399
Reported release
53E
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2014-01-24
Closed date
2014-01-24
Last modified date
2016-05-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX 5.3 EXT SUP
Fixed component ID
5765G0399
Applicable component levels
R53E PSY
UP