IV53134: MUSENT_EEH_ENTRY LOGGED WHEN DRIVER IS IN DEAD STATE APPLIES TO AIX 5300-12

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • MUSENT_EEH_ENTRY gets logged when driver is in DEAD state and
    entstat or netstat is run on the device to query statistics.
    

Local fix

Problem summary

  • Multiple MUSENT_EEH_ENTRY entries are logged in errpt for
    FC1763 and FC5899 adapters when driver is in DEAD state and
    entstat or netstat is run on the device to query statistics.
    

Problem conclusion

  • Change driver code to prevent adapter access in DEAD state.
    

Temporary fix

Comments

  • 5300-12 - use AIX APAR IV53134
    6100-07 - use AIX APAR IV58324
    6100-08 - use AIX APAR IV51018
    6100-09 - use AIX APAR IV51891
    6100-09 - use AIX APAR IV51891
    6100-09 - use AIX APAR IV51891
    7100-01 - use AIX APAR IV57578
    7100-02 - use AIX APAR IV57121
    7100-03 - use AIX APAR IV51624
    

APAR Information

  • APAR number

    IV53134

  • Reported component name

    AIX 5.3 EXT SUP

  • Reported component ID

    5765G0399

  • Reported release

    53E

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2013-12-09

  • Closed date

    2013-12-09

  • Last modified date

    2014-08-14

  • APAR is sysrouted FROM one or more of the following:

    IV51018

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX 5.3 EXT SUP

  • Fixed component ID

    5765G0399

Applicable component levels

  • R53E PSY

       UP

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11P","label":"APARs - AIX 5.3 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"53E","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 August 2014