IBM Support

IV52726: TWO OR MORE NMON RECORDING WITH SAME FILENAME NOT GIVING ERROR

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Two or more nmon recording with the same user given filename
    (-F option) succeeds with the file overwritten by succeeding
    recording
    

Local fix

Problem summary

  • Two or more nmon recording with the same user given filename
    (-F option) succeeds with the file overwritten by succeeding
    recording
    

Problem conclusion

  • Two or more nmon recording with the same user given filename
    should not be allowed in the first place. If the File already
    exists, nmon recording will throw appropriate error message
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV52726

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2013-12-02

  • Closed date

    2013-12-02

  • Last modified date

    2014-05-23

  • APAR is sysrouted FROM one or more of the following:

    IV52326

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U859719

       UP14/05/22 I 1000

PTF to Fileset Mapping

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSMV87","label":"AIX 6.1 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMVAX","label":"AIX Express Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11R","label":"AIX 7.1 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
23 May 2014