A fix is available
APAR status
Closed as program error.
Error description
Doing multibos with updates can fail: Creating standby BOS boot image on boot logical volume bos_hd5 Could not load program ls: Symbol resolution failed for ls because: Symbol time64 (number 40) is not exported from dependent module /usr/lib/multibos_chroot/usr/ccs/lib/libc.a(shr.o). Examine .loader section symbols with the 'dump -Tv' command. /usr/sbin/bosboot■16: kernsize /= 1024: 0403-009 The specified number is not valid for this command. multibos: 0565-039 Error processing standby BOS boot image. multibos: 0565-035 Error setting up standby BOS.
Local fix
Problem summary
Doing multibos with updates can fail: Creating standby BOS boot image on boot logical volume bos_hd5 Could not load program ls: Symbol resolution failed for ls because: Symbol time64 (number 40) is not exported from dependent module /usr/lib/multibos_chroot/usr/ccs/lib/libc.a(shr.o). Examine .loader section symbols with the 'dump -Tv' command. /usr/sbin/bosboot 16 : kernsize /= 1024: 0403-009 The specified number is not valid for this command. multibos: 0565-039 Error processing standby BOS boot image. multibos: 0565-035 Error setting up standby BOS.
Problem conclusion
Use old version of commands.
Temporary fix
Comments
APAR Information
APAR number
IV18267
Reported component name
AIX V7.1
Reported component ID
5765H4000
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2012-03-26
Closed date
2012-03-26
Last modified date
2013-04-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.1
Fixed component ID
5765H4000
Applicable component levels
R710 PSY U849627
UP12/10/26 I 1000
PTF to Fileset Mapping
U849627 bos.rte.bosinst 7.1.2.0
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSMV87","label":"AIX 6.1 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMVAX","label":"AIX Express Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11R","label":"AIX 7.1 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"","label":""}}]