A fix is available
APAR status
Closed as program error.
Error description
removing hdisks while using the AIX active / passive pcm / DS 3, 5 and 5K may result in a hang in the PCM
Local fix
this is an unlikely timing event and may be resolved by placing the hdisk in a defined state prior to rmdev -Rdl the fscsi adapter pr pci bus
Problem summary
rmpath/rmdev command run on the active path of an AIX active/ passive disk(DS3K/DS4K/DS5K) may hang. All further IO to the disk may hang.
Problem conclusion
It should be ensured by using a timer that the fail over command is sent down even when there is no current IO on the active path of the disk.
Temporary fix
Comments
6100-04 - use AIX APAR IZ97794 6100-05 - use AIX APAR IZ97780 6100-06 - use AIX APAR IZ95321 7100-00 - use AIX APAR IZ98009
APAR Information
APAR number
IV04413
Reported component name
AIX 5.3
Reported component ID
5765G0300
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2011-08-03
Closed date
2011-08-03
Last modified date
2013-04-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX 5.3
Fixed component ID
5765G0300
Applicable component levels
R530 PSY U844846
UP11/10/07 I 1000
PTF to Fileset Mapping
U844846 devices.common.IBM.mpio.rte 5.3.11.6