Error description

  • If a line in /etc/rc.tcpip is commented out with
    multiple #'s like this:
    
    ##start /usr/sbin/dpid2 "$src_running"
    
    Running 'aixpert -c -p' will result in the following
    error message in /etc/security/aixpert/check_report.txt:
    
    rctcpip.sh: Daemon dpid2's status should be
    
    
    This will not happen if there is just one #.
    

Local fix

  • To get around this, make sure there is only one #:
    #start...
    

Problem summary

  • The customer will an invalid error message in the
    check_report.txt for aixpert if there is more than one #
    in a comment in the /etc/rc.tcpip file.
    

Problem conclusion

  • Modified the rctcpip script to handle more than one # in a
    comment.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV04214

  • Reported component name

    AIX 5.3

  • Reported component ID

    5765G0300

  • Reported release

    530

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2011-08-02

  • Closed date

    2011-08-02

  • Last modified date

    2013-04-16

  • APAR is sysrouted FROM one or more of the following:

    IV02281

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX 5.3

  • Fixed component ID

    5765G0300

Applicable component levels

  • R530 PSY U844676

       UP11/10/10 I 1000

PTF to Fileset Mapping

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11P","label":"APARs - AIX 5.3 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"530","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
16 April 2013